9
GENERAL CLEANING [TO BE PERFORMED BY STORE PERSONNEL]
AREA TO
CLEAN
FREQ.
INSTRUCTIONS
Case
Exterior
Daily
Acrylic:
Acrylic sneeze guard [and bins] must be cleaned with a mild soap
and water solution and a soft cloth.
Caution! Never use ammonia-based
cleaners on acrylic. Incorrect cleaning agents or abrasive cleaning
cloths cause surface to ‘cloud’ over time.
Daily
Glass Sneeze Guard:
Clean glass sneeze-guard (at top of unit) with a
household or commercial glass cleaner.
Daily
Containment Pans:
Remove. Submerge in mild soap and water solution
and clean thoroughly with brush. Allow to dry. Return pans to unit.
Weekly to
Monthly
Air Filter [With Magnetic Strip] on Rear Grille [Optional]:
Depending upon environment, it may be necessary to clean filter as often
as weekly. Filter MUST be cleaned at least monthly.
Remove from case. Submerse in warm, soapy water. Use soft-bristled
brush to remove dust, grease and grime that collects on filter. Rinse
thoroughly. After filter has dried, return to case.
See
REFRIGERATION FUNDAMENTALS
section in this manual for
illustrations.
Case
Interior
Daily
Deck:
Decks can be cleaned with a warm soap and water solution. For
stubborn stains/residue, decks can be removed and cleaned with soap and
water solution or submersed in hot, soapy water solution. Rinse thoroughly.
Dry. Return to case.
Weekly
Shelf Supports / Air Return Grilles / Decking
Wipe off shelf supports, air return grilles and decking with moist cloth.
Shelf supports can be removed for more thorough cleaning.
Air return grilles can be removed for more thorough cleaning.
Decking is NOT to be removed by store personnel.
Monthly
Condenser Coil:
Vacuum or brush grille condenser coil at case front. Use
metal or fiber brush to remove dust and dirt that can collect on condenser
coils. Be careful not to damage the fins on the coil. See
INSTALLATION