10
REFRIGERATION FUNDAMENTALS, CONTINUED: REFRIGERATION UNIT ACCESS / ILLUSTRATION
4. Refrigeration: Access, Connections & Servicing
Assembly or disassembly and servicing to be
accomplished by licensed refrigeration
contractor.
See illustration below for service connections.
Refrigerant lines are flexible to facilitate rear
access maintenance to condenser unit.
Filter Dryer
Receiver
Compressor
Electrical Box, Compressor
Electrical Box, Overflow Pan
Hot Gas Loop Condensate
Coils and Pan
Sight Glass
Overflow Pan (Electrical Coil)
Condenser Coils
Fan Shroud
Plastic glides are mounted to the unit base to
assist in sliding condenser out for access.
Note: condenser unit does not slide out front.
5. Refrigeration Package (Hot Gas Loop
System) - Enlarged View For Illustrative
Purposes Only
Front grille must be lifted up and off to access
refrigeration package.
See previous page for specifics on front grille
removal.
Enlarged view of condenser package is shown
below.