15
CONDITION
TROUBLESHOOTING
Control Display Is
Flashing
See your case’s serial label for your model’s specified settings. See
SERIAL
LABEL LOCATION & INFORMATION LISTED / TECH INFO & SERVICE
for
label location, etc.
Case Is Not Holding
Temperature
If a large amount of warm product was added to the case, it will take time for the
temperature to adjust. Unit needs product to be pre-chilled.
Temperature changes during defrost mode but will return to normal. Fourth LED
will indicate defrost cycle in progress.
Check that case is not in sun or near a heat or air-conditioning vent. See
OVERVIEW AND WARNINGS
section in manual for adverse conditions/
spacing issue parameters.
If case is located near front doors, temperature fluctuation can hinder unit’s ability
to maintain temperature. See
OVERVIEW AND WARNINGS
section in manual for
adverse conditions/spacing issue parameters.
Check that condenser coil air filter (attached to rear grille) has been cleaned.
See
GENERAL CLEANING (TO BE PERFORMED BY STORE PERSONNEL)
section in operating manual for instructions.
Check that condenser coil has been cleaned.
Check air return grilles for obstructions.
Check sight glass for flashing and/or low charge.
Check Set Point Temperature; it may be adjusted too high.
Condensing Unit Is
Not Operating
Check that the Main Power Switch is turned on.
Determine if temperature controller settings are properly set.
See your case’s
serial label for your model’s specified settings. See
SERIAL LABEL LOCATION &
INFORMATION LISTED / TECH INFO & SERVICE
section in manual
for label
location, etc.
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) - PAGE 3 of 3