25
PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER) - PAGE 3 OF 3
FREQUENCY
INSTRUCTIONS
Quarterly
Optional Clean Sweep™ Condensing Coil Cleaner:
Disconnect power from case
before servicing the Clean Sweep
™
Condenser Coil Cleaner!
Remove air intake grille (by lifting up and off); no screw removal is required.
Slide/roll out condensing package from underside of case assembly.
Remove the four (4) screws holding the Clean Sweep
™
rail intact.
Remove the Clean Sweep
™
rail.
Wash rails’ brushes in hot water and mild soap solution.
If brushes are worn, they must be replaced. Call Technical Service Department to
replace. Toll-Free number is listed at end of manual.
Clean condensing coil: Use air pressure or industrial strength vacuum; clean the
dust and dirt that may collect on the condenser coil.
Caution! Coil fins are sharp. Handle with care!
Reattach Clean Sweep
™
rail to condensing unit (4 screws).
Slide/roll condensing package back under case.
Replace air intake grille to case (4 screws).
See photos below.
(4) Screws
--- Above photos are taken after air intake grille has been removed from case ---
Brushes
Rail