24
PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER) - PAGE 2 OF 3
NOTE: PREVENTIVE MAINTENANCE IS TO
BE PERFORMED BY TRAINED SERVICE
PROVIDERS ONLY.
Preventive maintenance should be
performed quarterly (unless conditions
warrant a more frequent replacement cycle).
Honeycomb Air Diffuser Removal
A. Wedge non-metallic device of suitable
strength (such as a ballpoint pen or stylus)
between honeycomb and end panel.
Caution! Use care not to dislodge the heating
wire (that prevents condensation on the
honeycomb retainer).
B. Apply pressure to collapse the honeycomb to
allow it to be pulled out of honeycomb retainer.
C. Pry downward & away from honeycomb
retainer.
Clean honeycomb with warm water and soap
solution. Submerse if necessary. Use brush to
dislodge stubborn or sticky residue. Dry by
using vacuum’s ‘blow mode’.
Honeycomb Air Diffuser Installation
D. Squeeze honeycomb into the honeycomb
retainer.
E. Carefully slide honeycomb into place.
F. Adjust honeycomb so that it fits flat against
retainer. It must not be wavy or out of position.
A
B
C
D
E
F
Honeycomb
Air Diffuser