25
PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER) - PAGE 3 OF 3
FREQUENCY
INSTRUCTIONS
Quarterly
Optional Clean Sweep™ Condensing Coil Cleaner:
Disconnect power from case
before servicing the Clean Sweep
™
Condenser Coil Cleaner!
•
Remove air intake grille (by lifting up and off); no screw removal is required.
•
Slide/roll out condensing package from underside of case assembly.
•
Remove the four (4) screws holding the Clean Sweep
™
rail intact.
•
Remove the Clean Sweep
™
rail.
•
Wash rails’ brushes in hot water and mild soap solution.
•
If brushes are worn, they must be replaced. Call Technical Service Department to
replace. Toll-Free number is listed at end of manual.
•
Clean condensing coil: Use air pressure or industrial strength vacuum; clean the dust
and dirt that may collect on the condenser coil.
•
Caution! Coil fins are sharp. Handle with care!
•
Reattach Clean Sweep
™
rail to condensing unit (4 screws).
•
Slide/roll condensing package back under case.
•
Replace air intake grille to case (4 screws).
•
See photos below.
(4) Screws
--- Above photos are taken after air intake grille has been removed from case ---
Brushes
Rail