STUDER INNOTEC
XP-COMPACT
XP-COMPACT
V5.4
11/77
3.3.2
Protection cover of the terminals
connections
The protection is available as an option (Order ref.
CFC-01) and avoid to do wrong hazardous
connection on the terminals 230Vac. It mounted
with strain relief clamps for the cable.
3.4 Connection
Plan
A B/-
Battery cable (already installed)
B SOLAR +/-
Connection terminal for Solar modules
C Remote contr.
Connection terminal for Remote Control RCC-01
D Equalize
Slide switch for equalization of the Battery
E Transfer delay
Slide switch for Transfer Delay
F Temp.
Connection terminal for Temperature sensor CT-35
G Aux. Contact
Connection terminal for Auxiliary Contact
H AC
Input
Connection terminal for AC-input. Located directly
above this terminal is the automatic safety cut-out for
this terminal.
J ID Plate
Identification plate with Technical data and Serial
number
K AC
Output
Connection
terminal for AC-output
L Caution…
Caution: Check Polarity (+/-) before connecting the
battery !
M Don’t…
Do not open without disconnecting all terminals
N 16A Protection
16A Protection switch for the Transfer system