background image

Cabling Overview

Overall Connection

Remove the plastic Cover from the bottom side of the Xtender Inverter  and remove 
the front cover of the RCC-02 (1 screw)
Remove the back cover of the Xcom-CAN (2 back screws)

A- CAN Port 1 of the Inverter (Connects to RCC-02 Port-1) 

B- CAN Port 2 of the Inverter (Connects to Xcom COM Port-1)

C- CAN Port 1 of Xcom-CAN Connects to the battery CAN RJ45

WeCo

www.wecobatteries.com

A

A

B

B

C

Summary of Contents for Xtender-WeCo 4k4

Page 1: ...Quick Installation Guide Studer Xtender WeCo batteries READ THE MANUAL BEFORE INSTALLING THE BATTERY www wecobatteries com WeCo ...

Page 2: ...STUDER Xtender WeCo HeSU Battery STUDER Xcom CAN STUDER RCC 02 www wecobatteries com WeCo ...

Page 3: ...s 1400 48 xtm 2600 48 xtm 4000 48 xth 6000 48 xth 8000 48 variotrack variostring vt 40 vt 65 vt 80 vs 70 vs 120 5k3 4k4 Pro 4k4 Minimum configuration list Studer device Cont Power Peak Power 5sec VA Minimum amount of WECO batteries units 5k3 4k4 Pro 4k4 xts 1400 48 900 2 800 1 1 1 xtm 2600 48 2 000 6 500 1 1 2 xtm 4000 48 3 500 10 500 1 2 3 xth 6000 48 5 000 15 000 2 2 4 xth 8000 48 7 000 21 000 2...

Page 4: ...osening the two screws on the back side Change the DIP switch settings match the picture and the image below Jumper position as per below scheme 3 are used on a total of 4 jumpers kit WeCo www wecobatteries com ON DIP 1 ON 4 OFF 2 ON 3 ON 5 OFF 6 ON 7 OFF 8 ON ...

Page 5: ...and remove the front cover of the RCC 02 1 screw Removethe back cover of the Xcom CAN 2 back screws A CAN Port 1 of the Inverter Connects to RCC 02 Port 1 B CAN Port 2 of the Inverter Connects to Xcom COM Port 1 C CAN Port 1 of Xcom CAN Connects to the battery CAN RJ45 WeCo www wecobatteries com A A B B C ...

Page 6: ...t 2 of Xcom remains empty LED GREEN Make sure the LED blinks 2 times interval and repeats If the LED blinks Green RED check the connection again because the communication is not correct If the LED is RED the connection is wrong WeCo www wecobatteries com A B B Termination Switch to the right of the two RJ45 Ports Termination Switch to the right of the two RJ45 Ports Set Switch to the right Set Swi...

Page 7: ...RG45 Port T O A COM Port 1 of the RCC 02 RCC 02 COM Port 2 is not used B COM Port 1 of the Xcom ComBus Side C CAN Port 1 of the Xcom CAN Side Connected to battery CAN RJ45 O T All termination switches are set to the left www wecobatteries com WeCo A B A B Termination Switch to the right of the two RJ45 Ports C ...

Page 8: ...RCC 02 Battery Infos RCC 02 must show the information as per the picture above WeCo www wecobatteries com ...

Page 9: ...ow only limited battery information or N A Once the communication is correct try to disconnect the CAN cable from the battery to the X Com must show a RED BACKGROUND Reconnect the CAN cable and the RCC 02 Display must show the info 226 communication restored see pic above WeCo www wecobatteries com ...

Page 10: ...WeCo www wecobatteries com ...

Page 11: ...ake sure that all the LED are OFF and measure the terminal output with a Volt meter No LED lights should be visible in when the battery is in OFF MODE status Make sure the output is ZERO Volts with a Voltmeter before operating on the battery terminal block WeCo www wecobatteries com ...

Page 12: ...osition of the DIP switch move it as shown in the picture 5th PIN enable the CAN In Out comm Attention any action on the DIP Switch must be followed by a reset of the battery with a long press of the ON OFF button www weco uk com WeCo CAN BMS PORT ON DIP 1 OFF 2 OFF 4 OFF 5 ON 3 OFF ...

Page 13: ...WeCo www wecobatteries com ...

Page 14: ...OT USE WITH STUDER INVERTER WeCo www wecobatteries com BATTERY BOTTOM SIDE CONNECTION From the original position of the DIP switch move it as shown in the picture 5th PIN enable the CAN In Out comm ON DIP 4 OFF 5 OFF 8 OFF 7 ON 1 OFF 2 OFF 3 OFF 6 OFF ...

Reviews: