Model 5402 User Guide
Issue 3, August 2021
Studio Technologies, Inc.
Page 27
Model 5402
DANTE LEADER CLOCK WITH GNSS SYNCHRONIZATION
When selected for Automatic the fields for the manual IP
address, subnet mask value, and gateway IP address will
be “grayed out” (will have a gray background) to indicate
that their values cannot be manually changed. In this con-
dition they are display-only. Changing between Automatic
and Manual and vice-versa will not impact the values stored
in the manual IP address, manual subnet mask value, and
manual gateway IP address fields.
Note that to minimize the chance of losing access to the
management web server, restoring the Model 5402’s
default configuration values will not change the currently
selected IP address configuration choice.
Manual IP Address:
This field shows the stored IP ad-
dress associated with the management web server when
the manual mode has been selected for the IP address
configuration. This address has nothing to do with the IP
address utilized by the primary and secondary Dante ports.
When IP address configuration is selected for Automatic
this field is grayed out and the value cannot be revised.
Whenever the IP address configuration is selected for
Manual the manual IP address can be modified as desired
to meet the requirements of the application. After entering
an IP address, using the standard dot-decimal notation,
the Submit button at the bottom of the webpage must be
pressed for the changes to be stored. A system reboot is
required for the revised manual IP address to be utilized.
The Reboot function is available on the system webpage
and the front panel. Restoring the Model 5402 to its default
values will not change the stored manual IP address.
Manual Subnet Mask Value:
This field shows the stored
subnet mask value associated with the management web
server when the manual mode has been selected for the
IP address configuration. When IP address configuration is
selected for Automatic this field is grayed out and the value
cannot be revised. When the IP address configuration is
selected for Manual this field will not be grayed out and the
value can be modified as desired to meet the requirements
of the application. After entering a revised subnet mask
value, using the standard dot-decimal notation format,
the Submit button must be pressed for the change to be
stored. A system reboot is required for the revised subnet
mask value to be utilized. Restoring the Model 5402’s
default values will not change the stored manual subnet
mask value.
Manual Gateway:
This field shows the stored gateway
value associated with the management web server when
the manual mode has been selected for the IP address
configuration. When IP address configuration is selected for
Automatic the manual gateway field is grayed out and the
value cannot be revised. When the IP address configura-
tion is selected for Manual this field will not be grayed out
and the value can be modified as desired. After entering
a revised gateway value, using dot-decimal notation, the
Submit button must be pressed for the change to be stored.
A system reboot is required for the revised gateway value
to be utilized. Restoring the Model 5402’s default values
will not change the stored manual gateway value.
Submit:
The Submit button is located at the bottom of the
Management Interface area of the Network menu webpage.
To save any changes made to four fields in the Manage-
ment Interface requires that the Submit button be pressed.
To utilize those changes requires that a Model 5402 reboot
to take place. That can occur by using the system Reboot
function on the system webpage or a selection on the front
panel’s menus.