38
Freq
:
ranges from 20 Hz to 200 Hz, with a default @ 100 Hz. Adjust the Frequency by
turning the main encoder or on the touch screen (fine tuning can be activated by pressing
the main encoder knob). Double press the parameter frame to set it as default.
⑤
EQ HS
Curve chart:
displays the HS curve
Gain
:
ranges is ±18 dB, with a default @ 0 dB. Adjust the Gain by turning the main encoder
or on the touch screen (fine tuning can be activated by pressing the main encoder knob).
Double press the parameter frame to set it as default.
Freq
:
ranges from 1.5 KHz to 15 KHz, with a default @ 6.3 KHz. Adjust the Frequency by
turning the main encoder or on the touch screen (fine tuning can be activated by pressing
the main encoder knob). Double press the parameter frame to set it as default.
⑥
Other parameter
Time:
the parameter can set the basic size of simulated room, ranges from 0 to 15s, with a
default @ 8s. To adjust by turning the main encoder or on the touch screen (fine tuning can
be activated by pressing the main encoder knob). Double press the parameter frame to set
it as default.
Chart 2 is time parameter range and default setting of different types.
Chart 2
Type Min
Max
Default
Hall Bright
0.8 s
12.0 s
1.6 s
Hall Warm
Room Bright
0.4 s
8.0 s
0.8 s
Room Warm
Plate Bright
0.4 s
6.0 s
0.6 s
Plate Warm
Pre Delay:
configure time of Pre Delay, ranges from 0~100ms, with a default @ 0ms. To
adjust by turning the main encoder or on the touch screen (fine tuning can be activated by