5. LOW BATT. : This graphical symbol, appeals when battery voltage goes
down to a low limit during discharge. The Digital
home UPS will shut
down automatically after a few minutes. During this stage the graphical
symbol glows and the buzzer gives continuous beep.
6. O.L. / SHORT CIRCUIT : This graphical symbol, shows that either
Short circuit has occurred or there is overload on the H
ome UPS. The
Digital Home UPS resets itself automatically and makes 8 attempts in
case of overload and 4 attempts in case of short circuit to switch ON. If
the overload or short circuit continues even after these attempts, the
Digital Home UPS switches OFF and will switch ON only after the
power active switch is first OFF and then put ON. In the event of
unsuccessful attempts the Digital Home UPS automatically shuts down.
During overload or short circuit the graphical symbol glows and the
buzzer gives a intermittent beep. If there is short circuit at the output,
the Digital Home UPS will switch OFF permanently after a few attempts.
It can be reset by repairing the short circuit and then switching OFF and
ON the power active switch.
7.
POWER ACTIVE SWITCH : The latching ON/OFF switch in the front is
to be pressed to ensure that the Digital Home UPS switch on in the event of
mains failure and connected load is energised by Digital Home UPS.