background image

REV. 08-02-07 

DIGITAL  

HOME UPS

 

The 

 has two battery wires coming out from the rear side,

a  Fuse  holder,  2  toggle  switches,  an  output  Socket  and  an  input  mains 

or 3 way cable .We connect the two battery wires to the terminals of the 

battery, the red coloured to positive terminal and the black coloured to the 

negative.  A  three  core  input  cable  has  to  be  used  to  connect  the 

  to  incoming  AC  Mains.  Ensure  that  incoming  phase  (or  line)  is 

connected to line (Red wire) neutral is connected to neutral (Black Wire) 

and  earth  is  connected  to  earth  (Green  Wire).  After  this  the  output  is 

connected  through  the  output  socket  at  the  rear  of  the

Digital Home UPS

home

UPS

  Home  UPS.

BACK PANEL:

REAR VIEW:

1.  3 Core Input Wire (Mains Input for Home UPS).

2.  15A  AC Output Socket.

3.  F6.3A/250V (Fast Blow) Fuse upto 800VA.

4.  Toggle Switch Narrow Window(UPS) / Wide   

Window (INV) mode.

5.  Toggle Switch Normal Charging Current (NC)/ 

  High Charging Current (HC) mode 

6.  Battery Wires. 

1. Position the Toggle Switch(4) at the rear panel of the Home UPS to 
Narrow window (UPS) mode if you want to run PC load otherwise always 
place the switch to  Wide Window(INV) mode.

2. Position the Toggle switch(5) to HC mode during frequent power cuts 
for fast charging of battery otherwise place to NC mode.

OUTPUT

OUTPUT

INV

(RED)

RED

(BLACK)

BLACK

GREEN

BATTERY WIRES

UPS

NC

HC

1

2

6

+

_

3

4

5

Note :

Back

Panel

Back panel view 600&800VA

Summary of Contents for COSMIC

Page 1: ... 7 Smart overload sense and short circuit protection 7 Automatic low battery cutout 7 PWM controlled efficient fast charging 7 Great power saving 7 User friendly LED indication Salient features GLOBAL CERTIFICATIONS GLOBAL CERTIFICATIONS GOVERNMENT OF INDIA GOVERNMENT OF INDIA MINISTRY OF SCIENCE TECHNOLOGY MINISTRY OF SCIENCE TECHNOLOGY R D R D Recognised Recognised ISO 14001 2004 Customer Care 9...

Page 2: ...d comments Su Kam is committed to continual product improvement and feel the best way to accomplish this task is by listening our valued customers This commitment gets strengthened every time you buy a Su Kam product We appreciate the support you have shown us through the purchase of our product Please read this manual to become familiar with its features and various applications Regards Su Kam Po...

Page 3: ...07 DIGITAL HOME UPS CONTENT KNOWINGYOUR HOME UPS A FRONT PANEL 1 2 B BACK PANEL 3 4 IMPORTANT SAFETY INSTRUCTIONS 4 5 6 SPECIAL NOTICES 6 TROUBLE SHOOTING 7 TECHNICAL SPECIFICATIONS 8 9 WARRANTY CARD 10 Contents ...

Page 4: ...al symbol shows that incoming mains is not available and the output is from Home UPS 3 BATT CHARGING CHARGED This white graphical symbol shows that the incoming mains is available and simultaneously the battery is also being charged This white graphical symbol glows intermittently during charging and glows continuously when battery is charged 4 FUSE BLOWN Mains fuse blows off when the Home UPS is ...

Page 5: ...t circuit continues even after these attempts the Digital Home UPS switches OFF and will switch ON only after the power active switch is first OFF and then put ON In the event of unsuccessful attempts the Digital Home UPS automatically shuts down During overload or short circuit the graphical symbol glows and the buzzer gives a intermittent beep If there is short circuit at the output the Digital ...

Page 6: ... through the output socket at the rear of the Digital Home UPS home UPS Home UPS BACK PANEL REARVIEW 1 3 Core Input Wire Mains Input for Home UPS 2 15A AC Output Socket 3 F6 3A 250V Fast Blow Fuse upto 800VA 4 Toggle Switch Narrow Window UPS Wide Window INV mode 5 Toggle Switch Normal Charging Current NC High Charging Current HC mode 6 Battery Wires 1 Position the Toggle Switch 4 at the rear panel...

Page 7: ...ails electricshockorfirehazard 4 Toreduceriskofelectricshock disconnectallwiringbeforecleaning OUTPUT OUTPUT INV RED BLACK UPS NC HC 2 6 _ 3 4 5 Input N E L 1 1 InputTerminal Block Mains Input for Home UPS 2 15A AC Output Socket 3 T10A 250V Slow Blow Fuse 4 Toggle Switch Narrow Window UPS Wide Window INV mode 5 Toggle Switch Normal Charging Current NC High Charging Current HC mode 6 Battery Wires ...

Page 8: ... GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION ProvideventilationtooutdoorsfromtheBatterycompartment Thebatteryenclosuresshouldbedesignedtopreventaccumulationand concentrationofhydrogengasin pockets atthetopofthecompartment Ventthebatterycompartmentfromthe highestpoint Aslopedlidcanalsobe used to direct the flow to the vent opening location To reduce the risk of battery explosion follow all the...

Page 9: ...g system IMPORTANTPRECAUTIONS The output side of the AC wiring should never be connected to a generator or incoming utility power This condition is far worse than a short circuit If the unit survives this condition it will shut down until correction is made Note Never disconnect the battery cables while the is delivering power or battery charger is operating The PowerActive Switch has no effect on...

Page 10: ...tteries and recharge Check and clean all connections Check allAC output connections Check for properAC input and output wiring Meter must be a true RMS reading meter Refer to cable and battery recommendations in this manual Weak batteries battery cable too long Measuring with the wrong typeVoltmeter Reduce the load and restart Home UPS through Power Active Switch Reduce the load and replace the gl...

Page 11: ...ATTERY CHARGING Microprocessor based Controlled SCR charging with Soft start over full range of mains 130V to 290V Mains Output Frequency Same as Input 45 Hz 55Hz Output Frequency OUTPUT PARAMETER 50 0 Hz 0 1 Hz Technical Specifications Mains A C Low cut 105 5V Mains A C Low cut Recovery 120 5V Mains A C High cut 285 5V Mains A C High cut Recovery 275 5V VOLTAGE LIMITS WIDE WINDOW INV MODE OutputV...

Page 12: ...chnology TECHNOLOGY Storage Temp 0 50 C Operating Temp 0 40 C Humidity 0 90 Non condensing ENVIRONMENT Dimension W XDX H in mm Weight Kg 272X275X122 9 20Kg 300X300X130 10 10Kg 272X275X122 9 50 Kg 392X310X170 17 65 Kg 148X250X220 8 0Kg MODEL CAPACITY FRENDY 400VA 12V SONIK 600VA 12V TRUSTY 1400VA 24V SWAN 800VA 12V 800VA 12V COSMIC COSMIC DX Trusty don t have dual charging current setting NC HC opt...

Page 13: ...tative fire flood or other act of GOD and any other natural calamities and any other unauthorized repairs done or carried out will have to be borne by the purchaser The problem of fuse blown will not be included in the warranty of the product The services given for the same will be paid service The company in no way will be held liable for any loss or injury or damage caused to life or property or...

Page 14: ... 418302 Tel 020 32303900 09370658684 E mail pune su kam com Kolkata 75 Sarat Chatterjee road Police Station Lake Town Kolkata 700089 West Bengal Tel 91 9433266573 9339195150 E mail kolkata su kam com Vadodara L 20 2 Por Ramangamdi Indl Estate GIDC Por NH 8 Vadodara 391243 Gujarat Tel 91 9377111634 9327434081 E mail vadodara su kam com Indore 25 S D A Compound Lasutia Thana Devas Naka Indore 452001...

Reviews: