REV. 08-02-07
DIGITAL
HOME UPS
The
has two battery wires coming out from the rear side,
a Fuse holder, 2 toggle switches, an output Socket and an input mains
or 3 way cable .We connect the two battery wires to the terminals of the
battery, the red coloured to positive terminal and the black coloured to the
negative. A three core input cable has to be used to connect the
to incoming AC Mains. Ensure that incoming phase (or line) is
connected to line (Red wire) neutral is connected to neutral (Black Wire)
and earth is connected to earth (Green Wire). After this the output is
connected through the output socket at the rear of the
Digital Home UPS
home
UPS
Home UPS.
BACK PANEL:
REAR VIEW:
1. 3 Core Input Wire (Mains Input for Home UPS).
2. 15A AC Output Socket.
3. F6.3A/250V (Fast Blow) Fuse upto 800VA.
4. Toggle Switch Narrow Window(UPS) / Wide
Window (INV) mode.
5. Toggle Switch Normal Charging Current (NC)/
High Charging Current (HC) mode
6. Battery Wires.
1. Position the Toggle Switch(4) at the rear panel of the Home UPS to
Narrow window (UPS) mode if you want to run PC load otherwise always
place the switch to Wide Window(INV) mode.
2. Position the Toggle switch(5) to HC mode during frequent power cuts
for fast charging of battery otherwise place to NC mode.
OUTPUT
OUTPUT
INV
(RED)
RED
(BLACK)
BLACK
GREEN
BATTERY WIRES
UPS
NC
HC
1
2
6
+
_
3
4
5
Note :
Back
Panel
Back panel view 600&800VA