Table 188:
Description of the input-output relationship
VALID
OPEN
CLOSE
POSITION
Value
Description
0
-
-
0
Intermediate
1
0
0
0
Intermediate
1
1
0
1
Open
1
0
1
2
Closed
1
1
1
3
Bad State
9.8
Single point generic control 8 signals SPC8GAPC
SEMOD176448-1 v3
9.8.1
Identification
SEMOD176456-2 v3
Function description
IEC 61850
identification
IEC 60617
identification
ANSI/IEEE C37.2
device number
Single point generic control 8 signals
SPC8GAPC
-
-
9.8.2
Functionality
SEMOD176462-4 v10
The Single point generic control 8 signals (SPC8GAPC) function block is a
collection of 8 single point commands that can be used for direct commands for
example reset of LEDs or putting IED in "ChangeLock" state from remote. In this
way, simple commands can be sent directly to the IED outputs, without
confirmation. Confirmation (status) of the result of the commands is supposed to
be achieved by other means, such as binary inputs and SPGAPC function blocks.
The commands can be pulsed or steady with a settable pulse time.
9.8.3
Function block
SEMOD176479-4 v5
SPC8GAPC
BLOCK
PSTO
^OUT1
^OUT2
^OUT3
^OUT4
^OUT5
^OUT6
^OUT7
^OUT8
IEC07000143-3-en.vsd
IEC07000143 V3 EN-US
Figure 150:
SPC8GAPC function block
1MRK 505 384-UEN A
Section 9
Control
Breaker protection REQ650 2.2 IEC
317
Technical manual
Summary of Contents for impreza 2017
Page 1: ...RELION 650 SERIES Breaker protection REQ650 Version 2 2 Technical manual...
Page 2: ......
Page 32: ...26...
Page 42: ...36...
Page 50: ...44...
Page 168: ...162...
Page 226: ...220...
Page 396: ...390...
Page 498: ...492...
Page 512: ...506...
Page 528: ...522...
Page 632: ...626...
Page 650: ...644...
Page 738: ...732...
Page 784: ...778...
Page 785: ...779...