59
ENGLISH
CCR Diving
NO
DEPTH
DEPTH
DIVE TIME
DIVE TIME
MOD SP2
Selected ppO
2
SP2 x100
3. Press
to confi rm the switch. The text is shown for 5 seconds without blinking.
NO
DEPTH
DEPTH
DIVE TIME
DIVE TIME
Change to bottom setpoint confi rmed
To interrupt the switch process at any point, press 2x
.
Changing form bottom SP2 to SP1
Switching range
SP2 to SP1
Time
Depth
SP2 SP1/2
SP1
WARNING
When ascending the AMD (Absolute Minimum Depth SP2) switch depth is reached an audible warning goes off and
“SP1”, its MOD and the set ppO
2
blink for 30 seconds.