background image

AIRXCEL, INC. - SUBURBAN DIVISION

676 Broadway Street 

Dayton, Tennessee   37321

423-775-2131

www.Airxcel.com

INSTALLATION MANUAL

FOR FURNACE MODELS

 NT-16SEQ • NT-20SEQ

The design of these furnaces has been certified for installation in recreational vehicles only. In order for these furnaces to operate in conformity with 

generally accepted safety regulations, the installation instructions outlined in this book 

must be followed.

 Failure to comply with the installation 

instructions will void any responsibility of Airxcel, Inc., Suburban Division. Your furnace was inspected before it left the factory. If any parts are 

found to be damaged do not install the furnace. Any damages should be reported to the transportation company immediately and the appropriate 

claims filed.

WARNING!

 

Improper installation, adjustment, alteration, service or maintenance can cause property damage, 

personal  injury  or  loss  of  life.  Refer  to  the  installation  instructions  and/or  owners  manual  provided  with  this 

appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

INSTALLER:

 LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:

 RETAIN THIS MANUAL FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTIONS

WARNING!

 

Installation of this appliance must be made in accordance with the written 

instructions provided in this manual. No agent, representative or employee of Suburban or 

other person has the authority to change, modify or waive any provision of the instructions 

contained in this manual.

CAUTION: If possible, do not install the furnace to where the vent can be 

covered or obstructed when any door on the trailer is opened. If this is not 

possible, then the travel of the door must be restricted in order to provide 

a 6” minimum clearance between the furnace vent and any door whenever 

the door is open.

NOTE:

  The  exhaust  temperature  of  this  furnace  could  discolor  or  warp  some 

materials. You should verify that the material used on the coach door, panel, or 

cover will not discolor or warp from the exhaust temperature whenever any door, 

panel, or cover is in the open position.

CAUTION: Due to the differences in vinyl siding, this appliance should not 

be installed on vinyl siding without first consulting with the manufacturer 

of the siding or cutting the siding away from the area around the appliance 

vent.

CAUTION: In any installation in which the vent of this appliance can be 

covered due to the construction of the RV or some special feature of the 

RV such as slide out, pop-up, etc. always insure that the appliance cannot 

be operated by setting the thermostat to the positive “OFF” position and 

shutting off all electrical and gas supply to the appliance. Never operate 

furnace with vent covered.

These furnaces must be installed and vented as described in this manual so that 

the negative pressure created by the air circulating (return air) fan cannot affect 

the combustion air intake or venting of any other appliance. It is imperative that 

the  products  of  combustion  be  properly  vented  to  the  atmosphere  and  that  all 

combustion air supplied to burner be drawn from the outside atmosphere. (See 

“Installing Vent Assembly”.)

IMPORTANT:

 If this furnace is to be connected to a common duct system also 

serving a cooling unit, a manual or automatic damper is required to prevent any 

cold conditioned air from circulating back into the furnace. Cold air passing over 

the furnace combustion chamber during the operation of the cooling unit can result 

in  the  formation  of  condensation  inside  the  furnace  combustion  chamber. This 

condensation  may  promote  corrosion  and  premature  failure  of  the  combustion 

chamber.

NOTE:

  These  furnaces  shall  be  installed  so  the  electrical  components  are 

protected from water.

NOTE: Do not install the furnace with the vent facing toward the forward end 

of the coach.  

See figures 11 and 12.

These  furnaces  will  accommodate  an  installation  depth  from  23  3/8”  minimum 

(with standard vent tubes), to 30 1/8” maximum (with optional intake extension 

tubes). (See Figure 1.)

Please adhere strictly to the installation instructions to insure proper installation 

and safe operation, as well as adequate clearances for accessibility.

These  furnaces  are  certified  for  use  with  propane/LP  gas  only.  Gas  supply 

pressure for purposes of input adjustment:

 GAS  MINIMUM

 MAXIMUM

Propane/LP

11” W.C.*

13” W.C.*

*Water column

In the USA,

 the installation must conform with local building codes. In the absence 

of local building codes, refer to the latest edition of:

1. 

Standard for Recreational Vehicles NFPA 1192.

2. 

National Fuel Code ANSI Z223.1/NFPA 54.

3. 

The  furnace  must  be  electrically  grounded  in  accordance  with  the  latest 

edition of the National Electrical Code NFPA 70.

4. 

The installation of the furnace shall be in accordance with any applicable local 

codes and regulations.

In Canada,

 the furnace must be installed in accordance with:

1. 

Standard CAN/CSA Z240.0.2-08 Recreational Vehicles.

2. 

CSA  Standard  CAN/CSA  Z240.6.2-08/C22.2  No.  148-08  Electrical 

Requirements for Recreational Vehicles.

3. 

Standard  CAN/CSA  Z240.4.2-08  Installation  Requirements  for  Propane 

Appliances and Equipment in Recreational Vehicles.

4. 

CAN/CGA-B149 Installation Codes

5. 

Any applicable local codes and regulations.

The furnace cabinet must extend through the coach cabinetry 1 3/8” as shown 

in Figure 1. The 1 

3

/

8

” extension must be held in order to assure that the front 

grille will properly attach to the furnace cabinet. Adequate clearances must be 

maintained around furnace cabinet so that the unit will be accessible for servicing.

TO INSTALL THE FURNACE

1. 

Locate  the  furnace  near  lengthwise  center  of  the  coach.  Do  not  install  the 

furnace with the vent facing toward the forward end of the coach.

2. 

Select a location for installation out of the way of wires, pipes, etc. that might 

interfere with installation. Adhere to the following minimum clearances from the 

furnace cabinet to combustible construction.

   

Back - 0” 

Top - 5/8”

   

Floor - 0” 

Sides - 5/8”

NOTE:

 Side and top clearances of furnace cabinet may be 0” for through the wall 

installations up to a maximum of 2 

1

/

2

” wall thickness (See Figure 2.)

The  following  minimum  clearances  from  the  warm  air  discharge  grille  to 

combustible  materials  must  be  maintained:    See  Figure  10  for  0”  clearance  of 

grille if framed.

MODELS NT-16SEQ,  NT-20SEQ

Front 24”

Top 1”

Floor 

1

/

4

Left Side 1” Right Side 8”

or (See Figure 8)

Left Side 8” Right Side 1”

REDUCED FRONT CLEARANCE

NT-16SEQ Front 12”

Top 1”

Floor 

1

/

4

NT-20SEQ Front 18”

Top 1”

Floor 

1

/

4

Note:

  Must provide an additional 12 sq. in. of return air when side clearance 

is 1” - 8” (See Figure 9)

3. 

When an appliance is installed directly on carpeting, tile, or other combustible 

material other than wood flooring, the appliance shall be installed on a metal 

or wood panel extending the full width and depth of the appliance. If preferred, 

the  carpeting,  tile  or  combustible  materials,  other  than  wood  may  be  cut 

away the full length and depth of the appliance plus the appliance minimum 

clearances to combustibles.

4. 

Cut or frame an opening in the coach cabinetry 10 

9

/

16

” x 10

 3

/

16

” as shown in 

Figure 2 or Figure 3.

5. 

Slide the front of the furnace through the opening and extend it beyond the 

coach cabinetry 1 

3

/

8

” as shown in Figure 2 or Figure 3.

6. 

Determine “X” dimension as shown in Figure 1.

7. 

Determine “Y” dimension as shown in Figure 1.

Part Number 205164

01-28-2015

Summary of Contents for NT-16SEQ

Page 1: ... promote corrosion and premature failure of the combustion chamber NOTE These furnaces shall be installed so the electrical components are protected from water NOTE Do not install the furnace with the vent facing toward the forward end of the coach See figures 11 and 12 These furnaces will accommodate an installation depth from 23 3 8 minimum with standard vent tubes to 30 1 8 maximum with optiona...

Page 2: ...em used to power the furnace be wired in parallel with the battery This will serve two purposes 1 Provide a constant voltage supply to the furnace 2 Filter any A C spikes or volt surges NOTE Furnace models NT 16SEQ AND NT 20SEQ are equipped with an electric ignitor device that has an energy consumption of 1 amps at 12 volts D C CONNECTING THERMOSTAT The thermostat used with this unit must have NO ...

Page 3: ... 3 16 13 4 6 1 16 9 5 16 1 4 3 15 16 3 1 2 1 9 32 21 2 BACK VIEW OF FURNACE Figure 4 INSTALLING VENT CAP IMPORTANT VENT CAP AND TUBE ASSY MUST BE INSTALLED FROM OUTSIDE OF COACH TRAILER SKIN OUTLINE OF FURNACE VENT CAP EXHAUST TUBE ASSEMBLY HOLE DIA IN OUTER SKIN MAY BE 2 1 4 IF OPENING CUT IN COMBUSTIBLE WALL IS CUT AS ILLUSTRATED IN FIGURES 3 OR 4 HOLE DIA MUST BE 2 3 4 IF THE 4 X 7 1 2 OPENING ...

Page 4: ...BL WH POWER TO THERMOSTAT R 12 V D C Y 12 V D C BL THERMOSTAT MOTOR SWITCH SAIL N O LIMIT SW N C N C SWITCH VALVE ELECTRODE MODULE BOARD THERMOSTAT N O VALVE V V 340570 12 VOLTS D C VALVE NO 18 250 C RADIX WIRE UL 3257 Y BR POWER BL PWR BLO R BL WH BLUE WHITESTRIPES Figure 7 FRONT GRILL FRONT GRILL OBSTRUCTION ILLUSTRATION OF MINIMUM SIDE CLEARANCES WITH A MINIMUM OF 24 CLEARANCE FRONT GRILL TO NE...

Page 5: ...AMED FRAME MAY BE AT 0 CLEARANCES TO TOP SIDES OF GRILLE AND EXTEND 1 3 4 MAX FROM BACK SIDE OF GRILLE THE1 4 BOTTOM CLEARANCE MUST BE MAINTAINED FOR RETURN AIR UNDER UNIT 1 3 4 MAX 1 4 INCORRECT INCORRECT Figure 11 CORRECT Figure 12 5 ...

Page 6: ...NTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH EACH LIMITED WARRANTY IS GIVEN SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER ...

Page 7: ...our la garantie de deux années À L EXCEPTION que Suburban ne remboursera aucun frais de main d oeuvre LIMITATION DES GARANTIES LA PÉRIODE DE VALIDITÉ DES GARANTIES IMPLICITES CECI INCLUANT LES GARANTIES IMPLICITES DE QUALITÉ MARCHANDE EST EXPRESSÉMENT LIMITÉE À LA DURÉE DE CHAQUE PÉRIODE DE GARANTIE LIMITÉE ACCORDÉE CERTAINES PROVINCES N ADMETTENT PAS LA LIMITATION DE LA DURÉE DE VALIDITÉ DES GARA...

Page 8: ...uls 0 po entre les parties supérieures latérales de l encadrement et la grille l encadrement doit dépasser de 1 3 4 po max à l arrière de la grille Pour la partie inférieure le dégagement de po doit être conservé pour permettre un retour d air sous l appareil INCORRECT INCORRECT Figure 11 CORRECT Figure 12 5 ...

Page 9: ...ECI PROVOQUERAIT DES DOMMAGES ET RENDRAIT INVALIDE LA GARANTIE DE L APPAREIL L APPAREIL A DEJA ETE TESTE AU FEU 100 R BR ELECTRIQUE VENTILQATEUR ELECTRIQUE BL WH BLEU RAYURES BLANC Figure 7 ILLUSTRATION DES ESPACES MINIMUM LIBRES NÉCESSITANT RETOUR D AIR ADDITIONNEL VERS L APPAREIL DE CHAUFFAGE CÔTÉ GAUCHE OU DROIT EST MOINS DE 8 UN ESPACE DE RETOUR D AIR ADDITIONNEL DE 12 POUCES CARRÉS EST NÉCESS...

Page 10: ...ULE DEUX TROUS À TRAVERS LA PAROI DU VÉHICULE DIAMÈTRE 2 1 4 PO Figure 3 LA VUE POSTÉRIÈRE DU CALORIFÈRE LE CABINET DU 2 1 4 D 2 LES TROUX LA SURFACE 7 64 D 4 TROUX 9 5 16 2 3 16 1 3 4 6 1 16 9 5 16 1 4 3 15 16 3 1 2 1 9 32 2 1 2 DE MONTAGE AU TRAVERS DE LA PEAU DE LA REMORQUE CALORIFÈRE LE PLAN DU CAPOT DE LA VENTOUSE Figure 4 L INSTALLATION DU CAPOT DE LA VENTOUSE LA PEAU DE LA REMORQUE LE PLAN ...

Page 11: ...sseur utilisé d actionner le calorifère soit câblé en parallèle avec la batterie Ceci servira deux objets 1 Fournir une alimentation de tension constante au calorifère 2 Filtre aucunes pointes de tension c a ou surtensions NOTE Les modèles NT 16SEQ et NT 20SEQ de calorifère sont équipés avec un mécanisme d igniteur électrique qui a une consommation d énergie de 1 amp à 12 volts C C BRANCHEMENT DU ...

Page 12: ...P 11 C E 13 C E Colonne d eau Aux U S A l installation doit conformer aux codes locaux de construction Dans l absence des codes locaux de construction veuillez vous référer à l édition la plus récente de 1 La Norme pour les Véhicules de Récréation NFPA 1192 2 Le Code National de Carburant ANSI Z223 1 NFPA 54 3 L apparel de chauffage être électriquement rellé à la masse conformément aux prescriptio...

Reviews: