Page 24
Install the Control Board
1
Place the bottom of the control board into the control board
bracket supports.
2
Push the top of the control board into the control board
bracket.
3
Insert the ribbon cables into the ribbon cable connectors
and lock the ribbon cable connector.
4
Connect the electrical connectors to the control board.
Install the Tank Housing Base
1
Insert the tank housing base into the control panel.
2
Use a T-20 Torx bit to install the screws into the tank
housing base.
Install the Valve Assembly
1
Place the valve assembly into the tank housing base.
2
Use a T-10 Torx bit to install the screws into the valve
assembly.
3
Install the drive motor tab into the notch in the tank housing
cover.
4
Connect the ground wires.
5
Connect the valve assembly electrical connectors.
6
Connect the water tank microswitch electrical connectors.
Install the Tank Housing Cover
1
Place the tank housing cover onto the tank housing base.
2
Use a T-10 Torx bit to install the screws into the tank
housing cover.
3
Install the wire harness clips onto the tank housing cover.
Install the Top Plate
1
Place the top plate on the unit.
2
Use a T-20 Torx bit to install the screws into the top plate.
Install the Water Tank Assembly
1
Install the water tank into the unit.
2
Push the water tank closed.
ROOM AIR FAN REMOVAL
To remove the room air fan, first remove the top plate.
Remove the Top Plate
1
Use a T-20 Torx bit to remove the screws from the top and
back of the unit.
2
Remove the top plate from the unit.
Remove the Room Air Fan
1
Disconnect the electrical connectors from the room air fan.
2
Rotate the room air fan clockwise.
CSO (SWS #13543126)
Top Component Removal and Installation
service.subzero.com
827703 REVA 02/2018
23