24 Ideal battery charging conditions
Admitted room temperature from 10°C to 35°C (ideal 20°C)
Slow charge option (when permitted by the charger).
Battery temperature at charge start 20°C.
Conditions other than those described above may significantly influence charging as well
as the number of possible charges with acceptable yield.
25 Ideal battery depletion conditions
We recommend using batteries at a room temperature between 5°C and 35°C.
To avoid short term deterioration and potential cell polarity inversion, the battery
must not,
in any case, be fully depleted
. The automatic cut off device that prevents fully battery
depletion was installed for this reason.
25.1 Important note
After ADV use, always remember to cut off motor power using the circuit breaker.
This is because the ADV electronic control, even if the motor is not running, consumes a
small amount of energy which, in the long term, depletes the battery.
26 Battery polarity inversion
This phenomenon is due to battery overheating, where the positive pole of
one or more sells becomes negative and vice versa.
Consequently, during charge, voltage input by the battery charger,
required to restore the chemical reaction that generates power, moves in
the exact opposite direction to that useful, generating high cell overheating
in short circuit.
The phenomenon is rare, but may occur if the battery is used incorrectly.
Should you suspect that the battery was overheated, we recommend you
do not attempt to charge it, since hazardous, and contract SUEX customer
service who will make all necessary inspections.
IMPORTANT NOTE!
Also remember that the scooter inevitably stops running when the cut off device is
triggered. This event is not hazardous to the diver in any way since the dive was
planned taking into account that scooter use is not considered a safety device or