OPERATING MANUAL FOR SELECT EDI 60
L300180 Iss:A
16
Set Perm Quality Alarm
BACK
ENTER
0
15
µ
S
Set quality alarm
A minimum water quality is required to protect the EDI Cell from
fouling. An alarm can be set that will warn if the water quality exceeds
the set value (5-10us nom). Enter the desired water quality alarm limit
in the set quality alarm menu. During “Processing” should water quality
fall below this level the navigation bar on the mimic screen will display
“Poor Water Quality” alarm message. If the audible alarm is enabled a
buzzer will sound. If the water quality improves to below the set point
the alarm message will be removed from the screen and the buzzer will
stop sounding
The range of the alarm set point is between 15 – 25uS. The unit will be
set on delivery to 15uS. Setting a value lower than 15uS will disable
this alarm.
To change the displayed value simply use the
▲
,
,
up/down buttons
to either increase or decrease the value, pressing the “NEXT” button
will move the cursor to the next digit. Then press “NEXT” to save the
setting and return you to the “Settings Menu”.