6
9
10
Temporary Fixing Floor Guide
Hanging Door
11
Confirmation of Sliding Door Closer Operation
Remove the support under the door. Slowly move the
door toward door head, and confirm that sliding door
closer starts its function at approx. 115 mm before
full-close position.
Also, confirm that the door tail closer starts its
function at approx. 50 mm before full-close position.
If the closer is not working correctly, check the
Troubleshooting section.
Insert the roller until a click sound is heard.
Two-way Soft Closer
Upper roller
2
3
4
Floor guide
Support of 10 mm thickness
Lever
Upper roller
(main unit)
Upper roller
(casing)
Click
Confirm that upper roller main unit is not
dislocated from casing, for both door
head and door tail sides.
Do not close the door with excessive force. It
may cause damage or malfunction of soft close
mechanism.
Trigger
1
上
下
上
下
Mark
Mark
Lever
Lever
Position floor guide just below the
center of upper track.
The figure shows the position
of the model which has margin.
Front face of
door pocket
Trailing edge at
closed position
30
10
44
Elongated hole
Elongated hole
4
30
16
4
approx.115 mm