Loosen the screws and remove the cover.
The electronic or pneumatic proximity switches are set at
the factory.
c
OnnectiOn
eletric
Blue minus
Brown plus
Black
control pulse
Voltage
12-24V DC
Output current
max. 200mA
Output PNP
c
OnnectiOn
pneumAtic
Connection P
black
Connection A
yellow
Feed pressure at P
0-8bar
Signal pressure range at A
0 - feed pressure
2.2.3 p
neumAtic
AdVAnce
Attach air hoses (polyurethane hoses Di=4 mm, max.
pressure 7 bars, -35 to 60 °C ) to the installed pneumatic
connections.
For the quality of compressed air, see point 2.5!
w
ithOut
chip
remOVAl
Stroke «forward» (1). Stroke «back» (2).
w
ith
chip
remOVAl
Stroke «forward» (1). Stroke «back» (2). Release brake (3).
p
rinciple
OF
AdVAnce
cOntrOl
Machining unit (1). Oil brake (2). Inductive sensors (3). Ad-
justable speed regulation check valve (4). Bistable 4/2- or
5/2-way pulse valve (5). Main valve (6). Filter (7a). Pressure
regulator (7b). Oiler (7c). Mono-stable 4/2-way valve (only
with chip removal function) (8).
27
Summary of Contents for BEM 6
Page 2: ...English Spare Parts Français Pièces de rechange Deutsch Ersatzteile 2 2 ...
Page 3: ...Portugúes Peças de reposição Español Refacciones Italiano Pezzi di ricambio 3 3 ...
Page 4: ...English Spare Parts Français Pièces de rechange Deutsch Ersatzteile 4 4 ...
Page 5: ...Portugúes Peças de reposição Español Refacciones Italiano Pezzi di ricambio 5 5 ...
Page 8: ...English Outline dimension Français Croquis de dimensions Deutsch Massbilder 8 8 ...
Page 9: ...Portugúes Croquis cotado Español Croquis de dimensions Italiano Piano delle dimension 9 9 ...
Page 50: ...50 Portugúes Español Italiano English Français Deutsch ...
Page 51: ...51 Portugúes Español Italiano English Français Deutsch ...