background image

GB

at 90 PSI Operating Pressure

                      

         without  oil        with oil

Power                               300      330 Watt

Torque

LXC 4

2,5

3 Nm

LXC 2

5

6 Nm

LPC 2

5

6 Nm

Air  consumption

22

21,7 cfm

full load

0,63 0,62 m

3

/min

Air  consumption

24.5  24.1 cfm

no load

0,7

0,69  m

3

/min

No load speed

LXC 4

3200

4000 

rpm

LXC 2

1600

2000 

rpm

LPC 2

1600

2000 

rpm

Sound pressure level

ISO 15744

LXC 4

82  dB(A)

LXC 2 / LPC 2

80  dB(A)

Vibration

ISO 8662

< 2,5 m/s

2

weight without hose

LXC 4

0,93 kg

LXC 2

0,93 kg

LPC 2

0,91 kg

Recommended air quality

accord. DIN ISO 8573-1

3/4/4

Air hose ID

8  mm/5/16"

Grinding/Cutting wheels

150 mm/

(refer to APT catalog)

6"

Spindle  thread

M 14 or

(refer to spare part list)

5/8"-11

Machine components

1

Spindle

2

Right angle gear head

3

Water connector

4

Screw

5

Wrench 2 mm

6

Safety lever throttle

7

Ring throttle

8

Exhaust Hose

9

Muffler

10

Air hose

11

Wrench 22 mm

12

Wrench 17 mm

Adaptor kit

 (only for LXC2,LXC4)

13

Handle extension

14

Hexagon nut

15

Side handle

Recommended Accessories

16

Coupling with min ID 5.5 mm/ 7/32"

17

1/2" -Service Unit ( Capacity 5-8

Micron). with wet air include

Lubricator

Suitable Tools:

LXC 2/LXC 4

18

Elastic support plate with bayonet

fitting 

21

19/20

Surface grinding wheels / Grinding

rings / Grinding cups / Diamond tools.

LPC 2

Backing pads with fiber discs.

Additional Abrasives and Tools

can be found in the the SUHNER catalogs

Air supply requirements:

The DIN ISO quality specifications require, that

air is free of solid particles larger than 5

micron, remaining water content to be max. 6

g/m

3

 (pressure dew point +3 degree C) and

air may contain 5 mg/m

3

 of oil. Therefore

please observe the following:

• Operating with dirty and unlubricated air

reduces tool life substantially.

Before installing extension hoses, blow them

clean and minimize , if at all necessary

coupling and keep them clean.

• Rust will occur, if air supply is not lubricated

and wet. A few drops of air tool oil  from time to

time will prevent rust and stops bearings from

seizing.

• Conserve:

Put some drops of oil in the air inlet and briefly

blow through.

Safety Instructions:

• Do not exceed max. operating speed of tool

and clamping element.

• Observe accurate mounting of insert tools.

Technical  Data LXC 4 DH

LXC 2 DH

LPC 2 DH

Summary of Contents for LPC 2

Page 1: ...G INSTRUCTIONS Please read and save these instructions INSTRUCTIONS D UTILISATION Prière de lire et de conserver ISTRUZIONI PER L USO Si prega di leggere le istruzioni e di conservarle INSTRUCCIONES DE USO Lea y conserve estas instrucciones por favor LPC 2 LXC 4 LXC 2 ...

Page 2: ...ruckregler und bei feuchter Druckluft mit Öler Verwendbare Werkzeuge LXC2 LXC4 18 Elastische Lagerung mit Bajonettverschluss 21 19 20 Schleifscheiben Schleifringe Schleif töpfe Diamantwerkzeuge LPC2 Elastische Schleifteller mit Fiberscheiben Weitere verwendbare Werkzeuge sind in den SUHNER Katalogen aufgeführt Anforderungen an die Druckluft Die DIN ISO Qualitätsbezeichnung sagt aus dass die Luft f...

Page 3: ...ln Schleifkörper vor Schlägen Stössen sowie Fett schützen Falls die Geräuschentwicklung Schall druckpegel am Arbeitsplatz 85 dB A überschreitet sind Schall und Gehör schutzmassnahmen für den Benutzer erforderlich Weitere Sicherheitshinweis siehe bei liegende Broschüre No DL 39 220 01 Betriebsbedingungen Arbeitshinweise Ventilbetätigung Diese Maschine ist mit einem kombinierten Dreh Sicherheitshebe...

Page 4: ...m 7 32 17 1 2 Service Unit Capacity 5 8 Micron with wet air include Lubricator SuitableTools LXC 2 LXC 4 18 Elastic support plate with bayonet fitting 21 19 20 Surface grinding wheels Grinding rings Grinding cups Diamond tools LPC 2 Backing pads with fiber discs Additional Abrasives and Tools can be found in the the SUHNER catalogs Air supply requirements The DIN ISO quality specifications require...

Page 5: ...spanner 11 loosen parts 19 20 by nad or pull off Check concentricity use only vibration free tools and always observe M OS Max operating speed Observe mounting instructions for Mounted Stones Maintenance Store tool in a clean dry place Check the idling speed from time to time Even if the tool still gives satisfactory service have it checked by a trained mechanic after 300 to 400 operation hours or...

Page 6: ...ant un filtre capacité 5 8 micron régulateur de pression et lubrificateur en cas d air humide Outilsutilisables LXC 2 LXC 4 18 Palier élastique avec fermeture à baìonnette 21 19 20 Disques pour polissage de surface disques à tronçonner et à ébarber disques diamantés LPC 2 Support élastiques avec disques sur fibres Pour d autres outils veuillez consulter le catalogue SUHNER Réglementation pour l ai...

Page 7: ...r le matériau mais excercer un mouvement de va et vien en conduisant la meule au dessus du matériau Ne pas usiner des matières contenant de l amiante Changement d outils Débrancher la machine du réseau avant chaque changement d outil Maintenir le palier elastique 18 avec la clé 11 ensuite enlever et mettre en place l outil 19 20 à la main et serrer fortement Contrôler le faux rond de l outil et l ...

Page 8: ...à 5 8 micron pressostato e in caso di aria compressa umida oliatore Utensiliutilizzabili LXC2 LXC4 18 Supporto elastico con attaco a baionetta 21 19 20 Mole utensili diamanti LPC 2 Platorello di supporto con dischi abrasivi I cataloghi SUHNER contengono ulteriori utensili utilizzabili Esigenze in materia di aria compressa La norma di qualità DIN ISO indica che l aria deve essere esente da particel...

Page 9: ...gliatura Assicurarsi che vi sia un asportazione di truciolo omogenea Evitare assolutamente un funzionamento rumoroso della macchina Non è consentita la lavorazione di materiali contenenti amianto Sostituzionedegliutensili Prima di eseguire il cambio utensile si deve scollegare la macchina dalla rete di aria compressa Bloccare sopporto elastico 18 con la chiave 11 e allentare o stringere forte gli ...

Page 10: ...terior de mín 5 5 mm 17 Unidad de mantenimiento de 1 2 integrada por filtro capacidad 5 8 micras regulador de presión y en caso de aire comprimido húmedo lubricador Herramientas utilizables LXC 2 LXC 4 18 Fijación elastica con cierre bayonete 21 19 20 Discos abrasivos piedras de amolar herramientas diamantados LPC 2 Plato abrasivo elástico con muela fibrosa Ver los catálogos de SUHNER por otras he...

Page 11: ...ango Quitar la tuerca 14 y cambiar la prolongación de mango 13 Amolar Prestar atención a un arranque uniforme de virutas es imprescindible evitar todo trabajo con sacudidas No deben trabajarse materiales que contienen asbesto Cambio de herramientas Antes de cada cambio de herramientas debe separarse la máquina de la red de aire comprimido Fijar la piedra 18 con llave 11 y desatar o fijar el abrasi...

Page 12: ......

Page 13: ...Local Distributor 39 279 01 11 00 SCHWEIZ Export Suhner Abrasive Expert AG Postfach 199 CH 5201 Brugg Tel 056 464 28 80 Fax 056 464 28 31 e mail sales export saeag ch http www suhner ch ...

Reviews: