Rotation direction: summer and winter options

The sliding switch controls the direction, whether clockwise or counterclockwise.

Summer option/down - 

or left-facing position (depending on the model) - The fan runs counterclockwise. The downwards air 

current creates a refreshing effect as indicated in diagram A.

Winter option/up - 

or right-facing position (depending on the model) - The fan runs clockwise. An ascending air current 

pushes hot air away from the fan area near the ceiling, as indicated in diagram B. This allows you to use less central heating.

Note:

 

Turn off the fan, lower the differential, and wait for it to come to a complete stop before changing the blade rotation 

direction with the sliding switch.

Balancing – Wobbling problems during fan operation

If the fan body wobbles during its operation, this is not a sign of malfunctioning (even if it wobbles a few centimeters). To 

reduce wobbling, you can, while the fan is off:

1. Check that all blades are properly fastened by tightening their screws.

2. Check the distance between each blade and the ceiling. Measurements to the ceiling can be carried out as shown in the 

following diagram. If variations exist and you have already correctly tightened the screws, check that all blades have the 

same shape. If any of them have a shape that is visibly different, this may be causing an imbalance during fan operation

If you have completed the previous steps and the wobbling has not resolved, you should apply dynamic balancing with the 

kit provided, as explained below:

1. Turn the fan on to the highest speed so that the greatest amount of wobbling is produced.

2. Turn off the fan. Select a blade and place a clip on it (see diagram) halfway between the fastening and the far edge of the 

blade.

1

2

Troubleshooting guide

Always consult this troubleshooting guide before contacting the technical service to avoid potentially unnecessary charges.

For your safety, ensure that the fan is not connected to power before attempting the solutions suggested in this troubleshoo-

ting guide.

Symptom

Probable causes 

Solution

1. The fan does not work 

(Important notice: The device 

must be disconnected from 

the power supply and the as-

sistance of a certified electri-

cian may be necessary)

A. The fuse is blown or the switch is “open”, disconnecting the 

power supply to the device

Check the fuses and switches on the device installation power circuit

B. System wiring connections are not adequately tightened

Check that wiring connections have been done correctly. They must 

be carried out by a certified electrician

.

C. The remote control is unresponsive

Replace the remote control battery if necessary. Otherwise, resyn-

chronize the transmitter and receiver.

D. No power supply

Check that the system has power and that it reaches the device.

2. Fan wobbling (follow the 

instructions in the “Wobbling” 

section of this manual)

A. The fan blades are not parallel to the ceiling

Follow the instructions indicated in the “Balancing” section of this 

manual.

B. Blade fastening screws are loose

Follow the instructions indicated in the “Balancing” section of this 

manual.

C. Deformed blades

Follow the instructions indicated in the “Balancing” section of this 

manual

.

3. Excessive noise when the 

fan moves

A. Upper canopy is touching the ceiling 

Lower the upper canopy, ensuring a separation from the ceiling of 

no less than 3 mm.

B. Blade fastening screws are loose

Tighten all fastening screws once again (but not excessively)

C. Ceiling mounting is loose

Retighten all ceiling mount screws

D. Incorrect remote control

Replace the remote control with that provided with the device. This 

must be supervised by a certified electrician. Contact the distributor

4. Mechanical noise

A. If this is the first use, leave the fan on for at least 8 hours. In the event that mechanical noise continues after this period, contact 

the technical service

5. The lights does not turn on

A. The light is defective

Replace the light

6. The fan turns but the air-

flow is inadequate

A. Incorrect blade rotation direction

The blades may be rotating in the opposite direction. Follow the di-

rections in the “Rotation Direction” section of this manual.

B. Inadequate distance between the ceiling and blades

Installing a fan without a shaft, flush with the ceiling, can reduce 

airflow.

C. Existence of nearby objects

There may exist objects in the room that block airflow.

D. Inadequate blade diameter

The fan chosen may be too small for the volume of the room where 

it is installed

Change in color temperature of the light.

You can change the color temperature of the light, turning off and on, with the wall switch, the remote control or in case of 

being an IoT fan from your terminal.

WARM

WARM

NEUTRAL

NEUTRAL

COLD

COLD

ON

ON

ON

ON

>20”

OFF

OFF

OFF

OFF

OFF

3. Turn on the fan and check whether the wobbling has improved or gotten worse. Turn it off once again and if the wobbling 

has not improved, place the clip on another blade. Repeat this process and determine on which blade it improves the 

wobbling.

4. Leave the clip on the blade that produces the best results. Move the clip forward or backwards on this blade until finding 

the position that offers the best results.

5. Afterwards, remove the clip and place one of the weights on the upper part of the center line of the blade at the position 

where the clip was located.

Summary of Contents for GAULAX 075706

Page 1: ... vídeos instrucciones y una guía de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 email info sulion es or with technical department at 916749483 email sat sulion es Before calling note of the reference name IMP located on the product sticker or next to the barcode on the box and d...

Page 2: ...rruptor de iluminación pues se produciría mal funcionamiento del ventilador y o daños en su motor Para la conexión eléctrica es preciso incorporar un interruptor seccionador de acuerdo con las reglamentaciones de instalación que asegure el corte omnipolar directamente conectado a los bornes de alimentación y debe tener una separación de contacto en todos sus polos que suministre desconexión total ...

Page 3: ...olar y justo a continuación dentro de los siguientes 15 segundos pulsar la tecla y del control remoto durante 10 segundos continuados 2 Un sonido de tipo beep indica que la conexión ha sido ejecutada y el equipo puede funcionar normalmente 3 Ahora control remoto y receptores de los ventiladores habrán quedad sincronizados Quite la corriente de los ventiladores mediane el interruptor o el automátic...

Page 4: ...e so lución de problemas Síntoma Causas probables Solución 1 El ventilador no funcio na Aviso importante El aparato debe encontrarse sin alimentación eléctrica y la asistencia de un electri cista autorizado puede ser necesaria A El fusible está fundido o el interruptor de la instalación está abierto desconectando la alimentación eléctrica al aparato Verificar el estado de fusibles e interruptores ...

Page 5: ...a cumplir el uso al que está destinado el titular de la garantía tendrá derecho a la sustitución del objeto adquirido por otro de idénticas características o la devolución del precio pagado Términos y condiciones de garantía www sulion es Congratulations on your purchase Congratulations on purchasing the latest energy efficient ceiling fan technology This fan uses DC current allowing for very high...

Page 6: ...chronization can be performed as indicated below Note in any case that there could be other reasons why your fan or remote control does not work Make sure all connections are correctly made Make sure that the remote control contains batteries Make sure that all switches main and isolation are on Instructions for synchronizing the receiver and the remote control The control of this fan does not req...

Page 7: ... that wiring connections have been done correctly They must be carried out by a certified electrician C The remote control is unresponsive Replace the remote control battery if necessary Otherwise resyn chronize the transmitter and receiver D No power supply Check that the system has power and that it reaches the device 2 Fan wobbling follow the instructions in the Wobbling section of this manual ...

Page 8: ...nne en courant continu DC ce qui lui permet d être d une grande efficacité énergétique tout en produisant un grand volume de circulation d air de manière silencieuse Efficacité énergétique Son moteur DC fait partie de la dernière technologie en matière de ventilateurs ce qui lui permet d économiser jusqu à 70 de l énergie consommée par des ventilateurs à courant alternatif AC traditionnels Fonctio...

Page 9: ...de l émetteur c est ce qu on appelle le processus d apprentissage Assurez vous que le ventilateur est débranché Ceci est essentiel pour le processus de synchronisation Si le processus de synchronisation n a pas réussi le ventilateur fonctionnera partiellement ou ne fonctionnera pas Par dé faut tous les ventilateurs ont été préconfigurés en usine et devraient être fonctionnels une fois l installati...

Page 10: ...se en garde importante L appareil n est pas alimenté électriquement et l aide d un électricien agréé peut être nécessaire A Le fusible a grillé ou le commutateur de l installation est ou vert ce qui déconnecte l alimentation électrique à l appareil Vérifiez l état des fusibles et des disjoncteurs du circuit d alimenta tion de l installation de l appareil B Le raccordement de l appareil n est pas c...

Page 11: ...eprise s engage à réparer gratuitement et totalement les défauts causés et les dommages et préjudices occasionnnés directement par ceux ci De même si la réparation n est pas satisfaisante et l objetneremplitpaslesconditionsoptimalespourl usageauquelilestdestiné letitulairedelagarantieauradroitàsonremplacement par un autre de caractéristiques identiques ou au remboursement du Prix d achat Termes et...

Page 12: ...sido bem sucedido o ventilador funcionará parcialmente ou não funcionará Por padrão todos os fãs foram pré configurados na fábrica e devem estar funcionando uma vez que a instalação está concluída e o ventilador está ligado Se o controle remoto não funcionar após a instalação ou durante o uso a sincronização pode ser realizada conforme indicado abaixo Note em qualquer caso que poderia haver outras...

Page 13: ...ode ser necessária a assistên cia de um técnico autori zado A O fusível está fundido ou o interruptor da instalação está aberto desligando a ligação elétrica do aparelho Verificar o estado dos fusíveis e dos interruptores do circuito de alimentação desde a instalação até ao aparelho B As ligações dos cabos da instalação não estão devidamente aper tadas Comprovar que as ligações dos cabos estão cor...

Page 14: ...o por outro de idênticas características ou a devolução do preçp que pagou Termos e condições de garantía www sulion es Gratulation zu Ihrem Kauf Herzlichen Glückwunsch zum Kauf der neuesten energieeffizienten Deckenventilator Technologie Dieser Ventilator arbeitet mit Glei chstrom wodurch eine sehr hohe Energieeffizienz und eine hohe Luftzirkulation ohne zusätzliche Geräusche ermöglicht wird Ener...

Page 15: ...Sender dies wird als Lernvorgang bezeichnet Stellen Sie sicher dass der Lüfter nicht angeschlossen ist Dies ist wichtig für den Synchronisationsprozess WennderSynchronisationsprozessnichterfolgreichwar arbeitetderLüfterteilweiseoderwirdnichtfunktionieren Standardmäßigsind alle Lüfter werkseitig vorkonfiguriert und sollten funktionieren sobald die Installation abgeschlossen und der Lüfter eingescha...

Page 16: ... Sie ob die Verkabelung korrekt ausgeführt wurde Sie muss von einer Elektrofachkraft durchgeführt werden C Die Fernbedienung reagiert nicht Ersetzen Sie gegebenenfalls die Batterie der Fernbedienung Andernfalls müssen Sender und Empfänger neu synchronisiert werden D Keine Stromversorgung Vergewissern Sie sich dass das System mit Strom versorgt wird und dass es das Gerät erreicht 2 Ventilatorwackel...

Page 17: ...h ein neues Gerät von identischen Eigenschaften oder die Erstattung des Kaufpreises verlangen Allgemeine Bedingungen für die Gewährleistung www sulion es Complimenti per l acquisto Congratulazioni per aver comprato il miglior ventilatore da soffitto per l efficienza energetica Questo ventilatore è alimentato in corrente continua e questo garantisce la massima efficienza energetica e un notevole ri...

Page 18: ... segnale dal trasmettitore questo è chiamato processo di apprendimento Assicurarsi che la ventola sia scollegata Questo è essenziale per il processo di sincronizzazione A meno che il processo di sincronizzazione non abbia avuto successo la ventola funzionerà parzialmente o non funzionerà Per impostazione predefinita tutte le ventole sono state preconfigurate in fabbrica e dovrebbero essere funzion...

Page 19: ... dispositivo è stato disconnesso dalla rete elettrica Controlla i fusibili e gli interruttori sul circuito di installazione del dispo sitivo B I cavi del sistema non sono collegati adeguatamente Controllare che i collegamenti siano stati effettuati correttamente Questi controlli devono essere effettuati da un elettricista qualificato C Il telecomando non risponde Se necessario sostituire la batter...

Page 20: ...ranno coperte della garanzia Eseguendo una manutenzione regolare per stringere questi elementi e pulire attentamente può prevenire questi problemi Oscillazioni Tutti i ventilatori da soffitto tendono a oscillare durante il funzionamento Un oscillazione di 2 cm è perfettamente accettabile e non è indice di alcun malfunzionamento né può causare la caduta del ventilatore se questo è stato fissato al ...

Page 21: ... EU ERP 2009 125 EC 2017 1369 206 2012 SULION declara bajo su propia responsabilidad que los productos abajo indicados han sido fabricados en conformidad con los siguientes estándares europeos SULION declare under our own responsibility that the products listed below have been manufactured in accordance with the following European standards SULION déclare sous sa responsabilité que les produits on...

Page 22: ......

Reviews: