background image

11

ENGLISH 

 

 

www.sulion.es

ATC: 

916749481 - info@sulion.es  /  

SAT :

 916749483 - sat@sulion.es

Congratulations on your purchase

Congratulations on your purchase of the latest in energy 

efficient ceiling fans.

Energy efficiency: 

SULION motors belong to the latest 

design technology in fans, saving up to 70% in energy 

consumption with DC motors.

Silent operation: 

Thanks to R&D advances in our motors, we 

have effectively reduced their operating noise in all models.

Comfort:

 DC motor fans include up to 6-speed remote 

control which provides superior comfort levels in their use. 

Safety precautions

Follow these instructions carefully to enjoy 

maximum safety in the installation and 

operation of this equipment.

The electrical installation of the ceiling fan must 

be carried out by an authorized electrician 

in order to be covered by our warranty. 

Please remember to require your installer to 

test all the fan functions before you leave. 

In case of any doubt from the installer, do not 

hesitate to contact us.

This device can be used by children aged 8 

years and above and people with reduced 

physical, sensory or mental abilities or lack 

of experience or knowledge, if they have 

been given appropriate supervision or training 

regarding the use of the device and they 

understand the dangers of its use. Children 

should not play with the device. The cleaning 

and maintenance of the device should not be 

carried out by children without supervision.

The fan must be installed in such a way that 

the blades are more than 2,3m above the 

ground. Make sure that there is a space of at 

least 30cm between the fan’s blades and any 

wall or other obstacle that they could hit. It is 

important to note that the greater the distance, 

the more efficient the air flow produced will 

be.

Any action performed for the electrical 

connection of the device, such as its cleaning, 

must be carried out after ensurin that the 

general power supply is disconnected, by 

removing the corresponding fuse or disarming 

the protective switch in order to ensure total 

isolation of the power supply. 

The system of attaching the fan bracket to the 

ceiling will depend on the type of ceiling where 

the installation is to be done. The decision 

on which attachment system to use and the 

quantity is the installer’s responsibility.

The fan must be installed at a location on 

the ceiling sch that the blades are at least 

2.3 m above the floor and 300 mm from any 

object or wall. The mounting bracket must be 

attached to a ceiling structure that is capable 

of supporting a minimum of 30 kg using the two 

screws provided. At least 30 mm of the length 

of the screws must be screwed into the bracket. 

When deciding where to mount the fan, be sure 

that there is at least 30 cm of space between the 

fan and any wall or other obstruction that the fan 

blades could collide with. The greater this distance, 

the more effective the air flow produced.After the 

fan is mounted, be sure that the blades are no less 

than 2.3 m above the ground

The ground wire of the fan must be connected to 

the earth network of the installation, to avoid any 

derivation that may put people in danger.

Do not connect the fan’s power supply to any 

dimmers, potentiometers, or light switches, as 

it will cause the fan to malfunction and/or will 

damage the motor. For the electrical connection it 

is necessary to incorporate a switch disconnector 

in accordance with the installation regulations, 

which ensures an omnipolar cut, directly 

connected to the power terminals and must 

have a contact separation at all its poles, which 

provides total disconnection under conditions of 

Category III overvoltage. The fan must be directly 

connected to a properly protected installation 

circuit (magnetothermal differential switch with 

the adequate size for the fan’s consumption and 

technical specifications). Only use the fan’s control 

to turn it on or stop it.

It is recommended not to use these types of fans 

along with gas installations simultaneously in the 

same room.

Do not insert anything that could hit the fan’s 

blades into its pathway while it is moving, as this 

could cause damage to people, can damage the 

blades, and can offset the balance of the unit, 

causing vibrations and wobbling.

 After installing the fan, ensure that all fastenings 

are secure and tightened in order to avoid any 

noise caused by loose elements.Due to the fan’s 

movement, certain fastenings may become loose. 

Check all fastenings twice per year at a minimum 

in order to ensure that they are sufficiently tight. If 

necessary, they must be retightened.

If the power cord is damaged, it must be replaced 

by the manufacturer, its after-sales service or 

similar qualified personnel in order to avoid any 

malfunction.

Only suitable for indoor. 

 Replaceable receiver and remote control

Do not throw away electrical products together 

with household waste. We ask you to recycle the 

packaging at the collection points provided for this 

purpose. Contact local authorities or your provider 

for recycling advice. Thank you for recycling at the 

collection points provided for this manual.

<8

Kg

OFF

OFF

Summary of Contents for MERIDA 075695

Page 1: ...deos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 em...

Page 2: ...2 ESPA OL Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 3: ...3 ESPA OL www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es...

Page 4: ...06 EN T l chargez le guide de l utilisateur sur notre site Web sulion es ean 8426107026606 FR Baixe o guia do usu rio em nossa web sulion es ean 8426107026606 PT DE Laden Sie die Bedienungsanleitung i...

Page 5: ...arantizar total aislamiento del suministro el ctrico Espa ol 05 English 11 Instalaci n del ventilador Fan installation 16 ndice Indice Index1 Componentes Parts Repuestos Spares Herramientas requeridas...

Page 6: ...y deben ser aportados por el usuario que cuida y disfruta de este ventilador La instalaci n debe de ser realizada por personal cualificado para realizar instalaciones el ctricas de acuerdo a la norma...

Page 7: ...IP20 Temperatura de trabajo 5 40 C Inclinaci n m xima del techo en el que se puede instalar 15 Peso 7 1Kg Consumo de energ a en modo de espera W 0 5 Norma de medici n del valor de servicio EN 62879 2...

Page 8: ...entro de los siguientes 15 segundos pulsar la tecla del control remoto durante 10 segundos continuados 2 Un sonido de tipo beep indica que la conexi n ha sido ejecutada y el equipo puede funcionar nor...

Page 9: ...do tal y como se explica a continuaci n 3 Encienda el ventilador en la velocidad m s alta para que se produzca mayor balanceo 4 Apague el ventilador Seleccione un aspa y coloque el clip ver figura en...

Page 10: ...alejado del agua y la humedad pues en caso contrario perder su garant a El sistema de anclaje del soporte del ventilador al techo depender del tipo de techo en el que se realiza la insta laci n La dec...

Page 11: ...acket must be attached to a ceiling structure that is capable of supporting a minimum of 30 kg using the two screws provided At least 30 mm of the length of the screws must be screwed into the bracket...

Page 12: ...in standby mode W 0 5 Service value measurement standard EN 62879 2020 Fan Speed 6 Power W 40 RPM 175 Airflow m min 200 Airflow m h 12000 Max noise level dB 45 Service value SV m min W 5 Maximum air...

Page 13: ...te control for 10 continuous seconds 2 A beep sound indicates that the connection has been executed and the equipment can function normally 3 Now transmitter and receiver of the fan s will have been s...

Page 14: ...to the highest speed so that the greatest amount of wobbling is produced 2 Turn off the fan Select a blade and place a clip on it see diagram halfway between the fastening and the far edge of the blad...

Page 15: ...supplier does not assume any liability for physical or bodily damage caused by the in correct use or installation of the fan If you are unsure consult an electrician Wobbling All ceiling fans tend to...

Page 16: ...16 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 Instalaci n ventilador Fan installation 1 2 3 2 1 1 2 3 OFF 03 04 02 01 05 06 07...

Page 17: ...17 www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es 1 2 70 NO INCLUIDOS NOT INCLUDED Green Yellow B la c k Brown Blue G re e n Y e ll o w W h it e Click 1 2 09 11 12 08 10...

Page 18: ...18 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 ON ON 1 2 3 15 13 14...

Page 19: ...uredinaccordancewiththefollowingEuropean standards DECLARACI N DE CONFORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60335 1 2012 A11 2014 A13 201...

Page 20: ...www sulion es...

Reviews: