Section 6
MAINTENANCE
31
Figure 6---12 Solenoid Valve (P/N 250017---993)
* Repair Kit P/N 250018---970
** Replacement Kit P/N 250018---971 (coil)
5. Reassemble in reverse order of disassembly.
COIL REPLACEMENT KIT (P/N 250018--971)
1. Remove the retaining clip.
2. Slip the yoke containing the coil and sleeves off
the solenoid base sub---assembly.
3. Reassemble in reverse order of disassembly.
6.7 TROUBLESHOOTING
The information contained in the Troubleshooting
chart is based upon both the reports about actual
field applications, and extensive testing done at the
factory. It contains symptoms and usual causes for
the described problems. However
DO NOT
as-
sume that these are the only problems that may oc-
cur. All available data concerning the trouble
should be systematically analyzed before under-
taking any repairs or component replacement pro-
cedures.
A detailed visual inspection is worth performing for
almost all problems. Doing so can prevent unnec-
essary damage. Always remember to:
a. Check for loose wiring.
b. Check for damaged piping.
c. Check for parts damaged by heat or an electrical
short circuit, usually apparent by discoloration
or a burnt order.
Should your problem persist after making the rec-
ommended check, consult your nearest Sullair
representative or the Sullair Corporation factory toll
free at 1---800---348---2722.
Summary of Contents for 10B 25HP
Page 2: ...NOTE For Additional Information on 24KT Units See Inside Back Cover...
Page 4: ...NOTES...
Page 22: ...16 NOTES...
Page 24: ...Section 4 INSTALLATION 18 Figure 4 1 Piping and Instruments...
Page 26: ...20 NOTES...
Page 42: ...36 NOTES...
Page 44: ...NOTES...
Page 45: ......