6.9 TROUBLESHOOTING GUIDE
SYMPTOM
PROBABLE CAUSE
REMEDY
Compressor Will Not Start
Main Disconnect Switch Open
Close switch.
Line Fuse Blown
Replace fuse.
Motor Starter Overload Tripped
Reset. Should trouble persist, check
whether motor starter contacts are
functioning properly.
Low Incoming Line Voltage
Check voltage. Should voltage check low,
consult power company.
Compressor Shuts Down With Air Demand
Present
Loss of Control Voltage
Reset. If trouble persists, check that line
pressure does not exceed maximum
operating pressure of the compressor
(specified on nameplate).
Low Incoming Voltage
Consult power company.
Excessive Operating Pressure
Separator requires maintenance; Check
maintenance indicator under full load
conditions.
High pressure setting in WS Controller set
wrong; reset.
Defective valve; regulator valve should
cause inlet valve to close when the pressure
switch contacts open. Repair if defective.
Defective blowdown valve; blowdown valve
should exhaust the receiver tank pressure
to 25 psig (1.7 bar) when maximum
operating pressure is reached. Repair if
defective.
Discharge Temperature Switch Open
Cooling air flow restricted
Ambient temperature is too high
Low fluid level
Clogged filter
Thermal valve not functioning properly
Clean cooler and check for proper
ventilation.
Provide sufficient ventilation.
Add fluid.
Change the fluid filter element.
Replace element.