6.9 TROUBLESHOOTING GUIDE (CONTINUED)
Liquid Water In Compressed Air Lines
Plugged Strainer in Moisture Drain Line
Clean and service strainer located in the line
off the bottom of the water separator.
Water Vapor Condensation from Cooling
and Compression Occurs Naturally
Remove the water vapor from compressed
air prior to distribution through the air
system. Check operation of aftercooler and
moisture separator. Install a compressed air
dryer sized for the flow and dryness level
required. (Note: Filters may also be required
to remove particulates, liquid oil aerosols or
for oil vapor removal. Change cartridges as
recommended by the filter manufacturer).
Check all drain traps routinely to insure their
proper operation. Maintain them regularly.
Defective Drain Solenoid Valve
Ensure valve opens and closes as signaled
by the WS Controller.
Inadequate Drain Timer Settings
Check WS Controller control drain interval
and drain time, and adjust accordingly. High
humidity conditions require longer drain
times or more frequent openings.
MAINTENANCE
®
SULLAIR
®
1100e, 1500e, 1800e Operator’s Manual and Parts List
45