Section 3
SPECIFICATIONS
16
LS--16 SERIES 60 Hz (CONTINUED)
MODEL (I)
HP/KW CAPACITY
LENGTH
WIDTH
HEIGHT(II)
WEIGHT(III)
dBA(IV)
(ACFM/M
3
/MIN)
(IN/MM)
(IN/MM)
(IN/MM)
(LB/KG)
w/ encl. /
w/o encl.
(Air--cooled)
L
60/45
286/8.10
72/1830
48/1220
60/1524
2590/1175
82/85
75/55
356/10.08
72/1830
48/1220
60/1524
2680/1216
82/85
H
60/45
268/7.59
72/1830
48/1220
60/1524
2590/1175
82/85
75/55
314/8.89
72/1830
48/1220
60/1524
2680/1216
82/85
HH
60/45
242/6.85
72/1830
48/1220
60/1524
2590/1175
82/85
75/55
279/7.90
72/1830
48/1220
60/1524
2680/1216
82/85
XH
75/55
256/7.25
72/1830
48/1220
60/1524
2680/1216
82/85
ENCLOSURE
(OPT) (V)
72/1830
48/1220
62/1588
500/227
COMPRESSOR:
STANDARD MODELS
Type:
Rotary Screw
Standard Operating Pressure
(VI):
100 psig (6.9bar) (L)
140 psig (9.7 bar) (HH)
115 psig (7.9bar) (H) (XH)
175 psig (12 bar) (XH)
Bearing Type:
Anti--Friction
Ambient Temperature (Max.)
(VII):
105
_
F (41
_
C)
Cooling:
Pressurized Fluid
Compressor Fluid:
Sullair Sullube
Sump Capacity:
8.0 U.S. gallons (30 liters)
Control:
Electro--Pneumatic
Supervisor II (optional)
MOTOR (VIII):
STANDARD MODELS
Size:
50, 60 and 75HP
Type:
C--Flanged, Open Dripproof, Premium Efficiency
Three Phase, 230/460 60 Hz, 380--415(400) 50 Hz
40
_
C Maximum Ambient Temperature
Options Available: 200V and 575V
T.E.F.C. Also Available: IP54
MOTOR (VIII):
STANDARD MODELS (CONTINUED)
Starter:
Full Voltage Magnetic or Wye Delta
Options Available: 200V and 575V 60 Hz, 220 50Hz
Speed:
1770 RPM (60 Hz) or 1475 RPM (50 Hz)
(I)
Includes standard and 24KT. Rated pressure designations appearing after model number are as follows:
“L” -- 100 psig /6.9 bar
“H” -- 115 psig/7.9 bar
“HH” --140 psig/9.7 bar
“XH”--175 psig/12 bar
Maximum pressure is rated pressure and 10 psig (0.7 bar).
(II)
An additional length of 4 in./102 mm is needed for servicing the separator; 9 in./229 mm for enclosure models.
(III)
Add 1450 lbs/658 kg for enclosure models.
(IV)
Ratings for dBA at one meter.
(V)
The weights shown for Enclosure do not include the weight of the compressor package.
(VI)
Special compressors are available for operation at higher pressures.
(VII)
Special compressors are available for operation in higher ambient temperature.
(VIII)
Multi--frequency and voltage motors are used. The compressors must be used only with the specified electrical frequency and voltage.
Summary of Contents for LS-10 series
Page 18: ...14 NOTES...
Page 22: ...Section 3 SPECIFICATIONS 18 Figure 3 1 Wiring Diagram LS12 LS16 Air cooled Water cooled...
Page 24: ...20 NOTES...
Page 28: ...24 NOTES...
Page 32: ...28 NOTES...
Page 35: ...NOTES...