Section 4
INSTALLATION
23
5. Reconnect the motor leads and jog the motor for
a dir ec tion of r otation c hec k as ex plained in
Sec -
tion 4.7
.
NOTE
Wiring diagram for standard compressors is sup-
plied on the inside cover of the Control Center.
Optional compressor wiring diagrams will vary.
4.7 MOTOR ROTATION DIRECTION CHECK --
STANDARD ELECTRO--MECHANICAL
NOTE
Motor rotation check must be made at compressor
start--up. Remove compressor panel as needed to
view motor rotation.
After the electrical wiring has been done, it is neces-
sary to check the direction of the motor rotation.
This can be accomplished by toggling between the
“I” (START)
and
“O” (STOP)
push buttons on the
control panel. Verify proper rotation by observing
the motor shaft from the end opposite the compres-
sor unit, the shaft should be turning clockwise. If the
motor shaft is not turning clockwise, disconnect the
power to the starter and exchange any two of the
three power input leads, then re--check rotation. A
“Direction of Rotation” decal is located on the motor
to show proper motor/compressor rotation.
An alternative to this procedure is to monitor the
sump pressure gauge when pressing the
“I”
(START)
push button. If immediate pressure is
shown on the sump pressure gauge when the com-
pressor is started, then the proper motor rotation
has been achieved. If no pressure is indicated,
press the
“O” (STOP)
push button immediately.
This indicates improper motor rotation. Disconnect
the power to the starter and exchange any two of the
three power input leads. Recheck rotation as out-
lined above.