Section 4
INSTALLATION
23
4.1 MOUNTING OF COMPRESSOR
A foundation or mounting capable of supporting the
weight of the compressor, and rigid enough to main-
tain the compressor frame level and the compres-
sor in alignment is required. The compressor frame
must be leveled and secured with foundation bolts,
and full uniform contact must be maintained
between the frame and foundation. It is recom-
mended that the frame be grouted to the founda-
tion. The compressor unit and driver must be
aligned after installation as specified in this
Operator’s Manual. No piping loads shall be trans-
mitted to the compressor or the cooling package at
the external connections.
4.2 VENTILATION AND COOLING
For air-cooled compressors, select a location to
permit sufficient unobstructed air flow in and out to
the compressor to keep the operating temperature
stable. The minimum distance that the compressor
should be from surrounding walls is 4 feet/1.22m.
To prevent excessive ambient temperature rise, it is
imperative to provide adequate ventilation.
For water-cooled compressors, it is necessary to
check the cooling water supply. The water system
must be capable of supplying flow rate as listed in
Table 4A - Water Cooling Supply Flow
.
Table 4B- Ventilation Requirements
indicates the
ventilation requirements necessary to keep the
compressor running at a normal operating temper-
ature. The fan air requirement is the volume of air
which must flow through the compressor for proper
ventilation. The specified heat rejection requirement
is the amount of heat that is radiated by the com-
pressor. This heat must be removed to assure a
normal operating temperature. With air-cooled com-
pressors it is possible to use this heat for space
heating, providing excessive pressure drop is not
created across the fan. Consult a Sullair office for
assistance in utilizing this heat.
DO NOT
install a water-cooled or an air-
cooled/aftercooled compressor without adequate
freeze protection where it will be exposed to tem-
perature less than 32ºF(0ºC).
4.3 SERVICE AIR PIPING
Service air piping should be installed as shown in
Figure
. A shut-off valve should be installed to
isolate a compressor from the service line if
required. Also notice that the service line should be
equipped with water legs and condensate drains
throughout the system.
Water flow requirements are based on 80°F to
85°F (27°C to 29°C) water inlet temperature.
Recommended water pressure range is 40 to 75
psig (2.8 to 5.2 bar). Water flow rates will vary
with operating conditions. For rates based on cri-
teria other than that listed, consult your local
Sullair representative.
Table 4B- Ventilation Requirements
WATER COOLED OR REMOTE COOLED
COMPRESSOR PACKAGE
AIR-COOLED
(I)
COOLING PACKAGE
MODEL
MOTOR HP / KW
HEAT REJECTION
BTU/HR
VENT FAN FLOW CFM
(II)
HEAT REJECTION
BTU/HR
AIR FLOW
CFM
LS20TS-300
300 / 224
80,136
2,800
801,360
21,600
LS20TS-350
350 / 261
89,000
2,800
890,000
21,600
LS20TS-400
400 / 298
111,400
2,800
1,114,000
21,600
LS20TS-450
450 / 336
114,400
2,800
1,144,000
21,600
LS20TS-500
500 / 373
127,800
2,800
-
-
LS20TS-600
600 / 447
152,640
2,800
-
-
(I)
Applicable to air-cooled models only.
(II)
Applicable to compressors with enclosure.
Table 4A - Water Cooling Supply Flow
MODEL - LS20TS
WATER FLOW
HP
KW
GPM
LPM
300
224
54
204
350
262
65
246
400
298
76
288
450
336
80
303
500
373
80
303
600
447
95
360
Summary of Contents for LS20T 1100 CFM
Page 18: ...Section 2 DESCRIPTION 12 Figure 2 3B Control System Diagram START...
Page 19: ...Section 2 DESCRIPTION 13 Figure 2 3C Control System Diagram MODULATION...
Page 20: ...Section 2 DESCRIPTION 14 Figure 2 3D Control System Diagram FULL LOAD...
Page 21: ...Section 2 DESCRIPTION 15 Figure 2 3E Control System Diagram UNLOAD...
Page 44: ...NOTES 38...
Page 104: ...Section 9 ILLUSTRATIONS AND PARTS LIST 98 02250146 367R00 9 19 CONTROL START SYSTEM...
Page 106: ...Section 9 ILLUSTRATIONS AND PARTS LIST 100 02250146 367R00 9 19 CONTROL START SYSTEM...
Page 108: ...Section 9 ILLUSTRATIONS AND PARTS LIST 102 02250138 633R00 9 20 CONTROL PANEL...
Page 110: ...Section 9 ILLUSTRATIONS AND PARTS LIST 104 02250139 119R01 9 21 ENCLOSURE...
Page 112: ...Section 9 ILLUSTRATIONS AND PARTS LIST 106 02250139 119R01 9 21 ENCLOSURE...
Page 114: ...Section 9 ILLUSTRATIONS AND PARTS LIST 108 9 22 DECAL GROUP...
Page 116: ...Section 9 ILLUSTRATIONS AND PARTS LIST 110 9 22 DECAL GROUP...
Page 118: ...Section 9 ILLUSTRATIONS AND PARTS LIST 112 9 22 DECAL GROUP...
Page 120: ...Section 9 ILLUSTRATIONS AND PARTS LIST 114 9 23 DECAL LOCATIONS OPEN AIR COOLED...
Page 122: ...Section 9 ILLUSTRATIONS AND PARTS LIST 116 9 24 DECAL LOCATIONS OPEN WATER COOLED...
Page 124: ...Section 9 ILLUSTRATIONS AND PARTS LIST 118 9 25 DECAL LOCATIONS REMOTE COOLER...
Page 126: ...Section 9 ILLUSTRATIONS AND PARTS LIST 120 9 26 DECAL LOCATIONS CONTROL BOX...
Page 128: ...Section 9 ILLUSTRATIONS AND PARTS LIST 122 9 27 ENCLOSURE DECALS...
Page 145: ...NOTES 139...