SERVICE AIR PIPING
Before installing the compressor, review the service
air system’s layout including: pipe sizes, auxiliary
separator tube, drip legs, line filter(s), and isolation
valves (See
P
IPE
S
IZING
Pipes should be sized as a minimum to match the
dimensions of the compressor’s discharge
connection. All piping and fittings should be rated for
the discharge pressure.
A
UXILIARY
R
ECEIVER
T
ANK
An auxiliary receiver tank should be installed in
systems where large demand fluctuations will occur.
NOTE
Systems using both reciprocating and
rotary screw compressors must isolate
the two types from each other through the
use of a common receiver tank. Air lines
from each individual compressor should
be connected directly to the common
receiver tank.