3: Specifications
02
250
247
-5
71 R0
4
Sub
jec
t to
EAR, ECCN
EAR99
and
rela
ted
exp
ort c
ontro
l res
tricti
ons
.
38
3.11 Piping & instrumentation, water-cooled—SN55, SN75
Key Description
Qty
1
FILTER, AIR
1
2
INDICATOR, RESTRICTION
1
3
VALVE,INLET
1
4
COMPRESSOR UNIT
1
5
MOTOR
1
6
FILTER, OIL
1
7
COOLER,OIL/WATER
1
8
VALVE, THERMAL
1
9
ORIFICE
2
10
GLASS,SIGHT/ORF
1
11
FILTER, ASSY
1
12
PLUG,SIGHTGLASS
1
13
PROBE, THERMISTER
1
14
VALVE, RELIEF
1
15
TRANSDUCER, PRESSURE
1
16
VALVE, SHUTTLE
1
17
VALVE, MIN PRESSURE
1
18
VALVE, BLOWDOWN
1
19
SEPARATOR,WTR
1
20
ELEMENT,SEP
1
21
VALVE,COMBO
1
22
STRAINER, V-TYPE
1
23
VALVE,SOLENOID 3WNO
2
24
VALVE, PRESSURE REG
1
25
TANK, SEPARATOR
1
26
FILTER,PNEUMATIC
1
27
VALVE,CHECK
2
28
HEAT EXCHANGER
1
29
SWITCH, PRESS
1
30
VALVE, WATER REG
1
31
VALVE,SOLENOID 2WNC
1
32
VALVE,BALL/STNR COMBO
1
33
DRAIN,ZERO LOSS
1
Drawing notes
1
CONTROL/MOISTURE DRAIN LINES ARE 1/4" TUBING EXCEPT AS
NOTED.
2
OPTIONAL HEAT TRACE IS APPLIED ONLY TO CONTROL AND
MOISTURE DRAIN LINES AND USED ONLY WITH STAINLESS
STEEL TUBING. REFER TO FACE OF ORDER FOR HEAT TRACE
REQUIREMENTS.
3
PARTS VARY BY MODEL.
Component
Description
P1
WET SUMP PRESSURE
P2
LINE PRESSURE
SOL1
LOAD/UNLOAD SOLENOID VALVE
SOL4
MEC/SEQUENCING/FULL LOAD SOLENOID VALVE
SOL5
COMBO DRAIN/JZL DRAIN SOLENOID VALVE
T1
WET DISCHARGE TEMPERATURE
Tubing color
Purpose
BLUE
TANK PRESSURE
YELLOW
REGULATOR PRESSURE
RED
UNLOAD PRESS
CLEAR
MOISTURE DRAIN