6.1 INTRODUCTION
While Sullair has built into the TS-32S Series
package a comprehensive array of controls and
indicators to assure its proper operation, the user
should recognize and interpret readings which call
for service or indicate the onset of a malfunction.
Before starting the unit, the user should become
familiar with the controls and indicators-their pur-
pose, location, and use.
6.2 PURPOSE OF CONTROLS
All Supervisor Controller related functions and indi-
cators are presented in the Supervisor Controller
Manual, so please refer to that manual for further
information. Additional indicators and functions
included in the package are as follows:
EMERGENCY STOP SWITCH
THERMAL O/L RESET
SULLICON ACTUATOR
SPIRAL VALVE
PRESSURE REGULATOR (SULLICON)
PRESSURE REGULATOR (WITH
SPIRAL VALVE)
SOLENOID VALVE #1
SOLENOID VALVE #2
DISCHARGE CHECK VALVE
Pushing in this switch, found adjacent to the Supervisor, cuts
all AC outputs from the Supervisor and de-energizes the
starter. A fault message (E STOP) is displayed by the
Supervisor until the button is pulled out and the “O” pad is
depressed.
Momentarily pushing this button, found on the starter’s ther-
mal overload element housing, re-closes the starter’s con-
tacts after a current overload takes place. Please be aware
that the elements must be allowed to cool sufficiently before
resetting.
Actuates the inlet butterfly valve which throttles the air flow to
the compressor inlet, in order to match air supply to the
demand.
Internally bypasses and controls the air flow capacity of the
compressor, in order to match air supply to the demand.
Opens a pressure line between the sump and Sullicon
Control allowing the Sullicon Control to regulate air delivery
according to the air demand.
Opens a pressure line between the service line and the spiral
valve actuator allowing the spiral valve to regulate air delivery
according to air demand.
Electrically actuated, 3-way valve which controls the flow of
pneumatic logic signals. Used throughout package to:
·
Open the blowdown valve.
·
Load the Sullicon device/close the inlet butterfly valve during
shutdown operation.
·
Open the spiral valve.
Opens when the compressor starts; closes when the com-
pressor is shut off. This prevents any air system loss and de-
pressurizes the controls when the compressor is shut off.
Blocks the reverse flow of air/fluid through the compressor
unit during shutdown.
6.2 PURPOSE OF CONTROLS (CONTINUED)
CONTROL OR INDICATOR
PURPOSE
Summary of Contents for TS-32S
Page 16: ...Section 2 DESCRIPTION 10 Figure 2 3A Compressor Cooling and Lubrication System Air cooled...
Page 17: ...Section 2 DESCRIPTION 11 Figure 2 3B Compressor Cooling and Lubrication System Water cooled...
Page 18: ...Section 2 DESCRIPTION 12 Figure 2 4A Compressor Discharge System Air cooled...
Page 19: ...Section 2 DESCRIPTION 13 Figure 2 4B Compressor Discharge System Water cooled...
Page 20: ...Section 2 DESCRIPTION 14 Figure 2 5A Control System START Typical...
Page 21: ...Section 2 DESCRIPTION 15 Figure 2 5B Control System MODULATION Typical...
Page 22: ...Section 2 DESCRIPTION 16 Figure 2 5C Control System UNLOAD Typical...
Page 23: ...Section 2 DESCRIPTION 17 Figure 2 5D Control System FULL LOAD Typical...
Page 27: ...Section 3 SPECIFICATIONS 21 NOTES...
Page 40: ...34 NOTES...
Page 48: ...42 NOTES...
Page 60: ...54 NOTES...
Page 63: ...57 NOTES...
Page 72: ...Section 8 ILLUSTRATIONS AND PARTS LIST 66 8 5 AIR INLET SYSTEM 02250135 499R01...
Page 114: ...Section 8 ILLUSTRATIONS AND PARTS LIST 108 02250135 534R03 8 20 SUMP AND PARTS...
Page 116: ...Section 8 ILLUSTRATIONS AND PARTS LIST 110 02250135 534R03 8 20 SUMP AND PARTS...
Page 118: ...Section 8 ILLUSTRATIONS AND PARTS LIST 112 02250134 158R00 8 21 SULLICON CONTROL...
Page 120: ...Section 8 ILLUSTRATIONS AND PARTS LIST 114 8 22 COMPRESSOR SPIRIAL VALVE ACTUATOR...
Page 124: ...Section 8 ILLUSTRATIONS AND PARTS LIST 118 02250135 643R05 8 24 PNEUMATIC CONTROLS...
Page 126: ...Section 8 ILLUSTRATIONS AND PARTS LIST 120 02250135 643R05 8 24 PNEUMATIC CONTROLS...
Page 128: ...Section 8 ILLUSTRATIONS AND PARTS LIST 122 02250135 643R05 8 24 PNEUMATIC CONTROLS...
Page 134: ...Section 8 ILLUSTRATIONS AND PARTS LIST 128 8 27 CONTROL BOX WYE DELTA TYPICAL 02250122 516R08...
Page 140: ...Section 8 ILLUSTRATIONS AND PARTS LIST 134 02250133 674R04 8 30 ENCLOSURE AIR COOLED...
Page 142: ...Section 8 ILLUSTRATIONS AND PARTS LIST 136 02250133 674R04 8 30 ENCLOSURE AIR COOLED...
Page 144: ...Section 8 ILLUSTRATIONS AND PARTS LIST 138 02250133 675R04 8 31 ENCLOSURE WATER COOLED...
Page 146: ...Section 8 ILLUSTRATIONS AND PARTS LIST 140 02250133 675R04 8 31 ENCLOSURE WATER COOLED...
Page 148: ...Section 8 ILLUSTRATIONS AND PARTS LIST 142 8 32 DECALS...
Page 150: ...Section 8 ILLUSTRATIONS AND PARTS LIST 144 8 32 DECALS...
Page 152: ...Section 8 ILLUSTRATIONS AND PARTS LIST 146 8 32 DECALS...
Page 154: ...Section 8 ILLUSTRATIONS AND PARTS LIST 148 8 33 DECAL LOCATIONS...
Page 156: ...Section 8 ILLUSTRATIONS AND PARTS LIST 150 8 34 DECAL LOCATIONS AIR COOLED ENCLOSURE TYPICAL...
Page 158: ...Section 8 ILLUSTRATIONS AND PARTS LIST 152 8 35 DECAL LOCATIONS WATER COOLED ENCLOSURE TYPICAL...
Page 160: ...Section 8 ILLUSTRATIONS AND PARTS LIST 154 8 36 DECAL LOCATIONS CONTROL BOX...
Page 162: ...Section 8 ILLUSTRATIONS AND PARTS LIST 156 8 37 DECAL LOCATIONS AFTER COOLER...
Page 171: ...NOTES...