SECTION 3
TS32 USER MANUAL
41
Figure 3-5: Piping and Instrumentation Diagram—Remote Air-Cooled
COMP
DESCRIPTION
P1
WET SUMP PRESSURE
P2
LINE PRESSURE
P3
INJECTION FLUID PRESSURE
P4
HIGH PRESSURE SIDE OF FLUID FILTER
PSW1
INLET FILTER VACUUM SWITCH
SOL1
LOAD/UNLOAD SOLENOID VALVE
SOL2
SPIRAL CONTROL SOLENOID VALVE (OPTIONAL)
SOL3
START CONTROL SOLENOID VALVE (OPTIONAL)
SOL4
MEC/SEQUENCING/FULL LOAD SOLENOID VALVE
(OPTIONAL)
SOL5
COMBO DRAIN/JZL DRAIN SOLENOID VALVE
SOL8
AUX. FLUID PUMP RELIEF SOLENOID VALVE
(OPTIONAL)
T1
WET DISCHARGE TEMPERATURE
T2
DRY DISCHARGE TEMPERATURE
T3
INJECTION FLUID TEMPERATURE
T4
INTERSTAGE AIR/FLUID TEMPERATURE
HTR1
SUMP HEATER
HTR3
TRAP HEATER
NOTES:
1.
PART NUMBERS ARE FOR REFERENCE ONLY. REFER TO BILL OF
MATERIAL AND OR FACE OF ORDER FOR ACTUAL PARTS.
2.
SECTION BETWEEN LETTERED POINTS ARE TO BE REPLACED
WITH CORRESPONDING OPTION PICTURED BELOW, AS
REQUIRED BY FACE OF ORDER.
3.
OPTIONAL HEAT TRACE IS APPLIED ONLY TO CONTROL AND
MOISTURE DRAIN LINES AND USED ONLY WITH STAINLESS
STEEL TUBING. REFER TO FACE OF ORDER FOR HEAT TRACE
REQUIREMENTS.
4.
ITEM 39 OR 41 TO BE INSTALLED BY SULLAIR BUT ELECTRI-
CALLY INSTALLED BY THE CUSTOMER IN THE FIELD.
5.
THE SUPPLY AND RETURN PIPING FOR THE FLUID COOLER
MUST BE ADEQUATELY SIZED TO PREVENT EXCESSIVE PRES-
SURE DROP. THE TOTAL PRESSURE DROP IN THE SUPPLY AND
RETURN PIPING AND ASSOC. FITTINGS AND VALVES SHALL NOT
EXCEED 10 PSIG (0.7 BAR). IF THE PRESSURE DROP IS EXCES-
SIVE, A PUMP MAY BE INSTALLED.
6.
MINIMUM OPERATING TEMPERATURE OF 32°F FOR LOWER
TEMPS. OIL LINES NEED TO BE HEATED AND INSULATED.
Summary of Contents for TS32 AC
Page 10: ...NOTES 10...
Page 15: ...SECTION 2 TS32 USER MANUAL 15 Figure 2 3 Compressor Piping and Instrument Diagram Typical...
Page 16: ...TS32 USER MANUAL SECTION 2 16 Figure 2 4 Compressor Cooling and Lubrication System Air cooled...
Page 18: ...TS32 USER MANUAL SECTION 2 18 Figure 2 6 Compressor Discharge System Air cooled 200 350HP...
Page 19: ...SECTION 2 TS32 USER MANUAL 19 Figure 2 7 Compressor Discharge System Water cooled 200 350HP...
Page 20: ...TS32 USER MANUAL SECTION 2 20 Figure 2 8 Control System START Typical...
Page 21: ...SECTION 2 TS32 USER MANUAL 21 Figure 2 9 Control System MODULATION Typical...
Page 22: ...TS32 USER MANUAL SECTION 2 22 Figure 2 10 Control System UNLOAD Typical...
Page 23: ...SECTION 2 TS32 USER MANUAL 23 Figure 2 11 Control System FULL LOAD Typical...
Page 26: ...TS32 USER MANUAL SECTION 2 26 Figure 2 12 Compressor Air Inlet System...
Page 30: ...TS32 USER MANUAL SECTION 3 30 Figure 3 2 Identification Air Cooled 02250126 376 R02...
Page 32: ...TS32 USER MANUAL SECTION 3 32 Figure 3 2 Identification Water Cooled 02250126 378 R03...
Page 50: ...TS32 USER MANUAL SECTION 3 50 Figure 3 9 Wiring Diagram Air Cooled SSRV 02250178 844 R03...
Page 54: ...NOTES 54...
Page 78: ...NOTES 78...
Page 79: ...NOTES 79...