SECTION 6
TS32 USER MANUAL
71
9. Clean the underside of the separator tank
cover and remove any rust.
10. Replace the cover plate, washers and 3/4-10
capscrews. Lubricate and Torque to 200 ft.-
lbs. (271 Nm).
11. Reconnect all piping making sure return line
tubes extend to the bottom or 1/4” (6mm)
above the bottom of the separator element.
This will assure proper fluid return flow to the
compressor.
12. Check the return line strainers before restart-
ing the compressor (order replacement kit
no. 02250117-782).
O
IL
R
ETURN
/
SIGHT
G
LASS
M
AINTENANCE
Refer to
. The oil return/sight glass
subassembly is attached to the separator tank lid.Oil
return/sight glass maintenance should be performed
on a routine basis parallel to that of the fluid filter, or
as indicated in the Troubleshooting Sections (both
Supervisor and Maintenance) of this manual. The
maintenance on an oil return/sight glass is mainly
concerned with the condition of the filter assembly.
Order filter assembly no. 02250117- 782, and use
the following instructions as a guide.
1. Disconnect the tubes at the tops of the sight
glass assemblies.
2. Unscrew male connector (for left-side glass),
or the straight thread tube connector (for
right-side glass) from sight glass/orifice
blocks.
3. Remove used filter assembly, and replace
with new assembly.
4. Coat/lubricate the O-rings will silicone
grease.
5. Reattach the connectors to the sight glass/
orifice blocks.
NOTE
Always performing maintenance on both oil
return/sight glasses at the same time.
Figure 6-4: Fluid Return / Sight Glass
(I) Replacement Filter Assembly P/N 02250117-782
Summary of Contents for TS32 AC
Page 10: ...NOTES 10...
Page 15: ...SECTION 2 TS32 USER MANUAL 15 Figure 2 3 Compressor Piping and Instrument Diagram Typical...
Page 16: ...TS32 USER MANUAL SECTION 2 16 Figure 2 4 Compressor Cooling and Lubrication System Air cooled...
Page 18: ...TS32 USER MANUAL SECTION 2 18 Figure 2 6 Compressor Discharge System Air cooled 200 350HP...
Page 19: ...SECTION 2 TS32 USER MANUAL 19 Figure 2 7 Compressor Discharge System Water cooled 200 350HP...
Page 20: ...TS32 USER MANUAL SECTION 2 20 Figure 2 8 Control System START Typical...
Page 21: ...SECTION 2 TS32 USER MANUAL 21 Figure 2 9 Control System MODULATION Typical...
Page 22: ...TS32 USER MANUAL SECTION 2 22 Figure 2 10 Control System UNLOAD Typical...
Page 23: ...SECTION 2 TS32 USER MANUAL 23 Figure 2 11 Control System FULL LOAD Typical...
Page 26: ...TS32 USER MANUAL SECTION 2 26 Figure 2 12 Compressor Air Inlet System...
Page 30: ...TS32 USER MANUAL SECTION 3 30 Figure 3 2 Identification Air Cooled 02250126 376 R02...
Page 32: ...TS32 USER MANUAL SECTION 3 32 Figure 3 2 Identification Water Cooled 02250126 378 R03...
Page 50: ...TS32 USER MANUAL SECTION 3 50 Figure 3 9 Wiring Diagram Air Cooled SSRV 02250178 844 R03...
Page 54: ...NOTES 54...
Page 78: ...NOTES 78...
Page 79: ...NOTES 79...