SECTION 6
TS32 USER MANUAL
77
Line Pressure Rises Above
Unload P2 Pressure Setting On
The Supervisor
Leak in control system causing
loss of pressure signals
Check for leaks.
Defective Solenoid Valve
Check that inlet valve closes when Supervisor
is in NO LOAD mode. Repair or replace if
necessary (kit available).
Defective Blowdown Valve
Check that sump pressure is exhausted to the
atmosphere when in the OFF LOAD mode.
Repair or replace if necessary (kit available).
Ruptured Sullicon control
diaphragm
Replace
Plugged Control Line Filter
Clean or repair if necessary.
Excessive Fluid Consumption
Clogged return line strainer or
orifice
Clean strainer (screen with o-ring replacement
kit available).
Clean orifice.
Separator element damaged or not
functioning properly
Check separator differential (plugged) dP1.
Change separator.
Leak in the lubrication system
Check all pipes, connections and components
Excess fluid foaming
Drain and change.
Fluid level too high
Drain excess fluid.
Pressure Relief Valve Opens
Repeatedly
Defective pressure relief valve
Replace pressure relief valve.
Liquid Water In Compressed
Air Lines
Water Vapor Condensation from
Cooling and Compression Occurs
Naturally
Remove the water vapor from compressed air
prior to distribution through the air system.
Check operation of aftercooler and moisture
separator. Install a compressed air dryer sized
for the flow and dryness level required. (Note:
Filters may also be required to remove
particulates, liquid oil aerosols or for oil vapor
removal. Change cartridges as recommended
by the filter manufacturer.) Check all drain
traps routinely to insure their proper operation.
Maintain them regularly.
Table 6-2: Troubleshooting Guide
SYMPTOM
PROBABLE CAUSE
REMEDY
Summary of Contents for TS32 AC
Page 10: ...NOTES 10...
Page 15: ...SECTION 2 TS32 USER MANUAL 15 Figure 2 3 Compressor Piping and Instrument Diagram Typical...
Page 16: ...TS32 USER MANUAL SECTION 2 16 Figure 2 4 Compressor Cooling and Lubrication System Air cooled...
Page 18: ...TS32 USER MANUAL SECTION 2 18 Figure 2 6 Compressor Discharge System Air cooled 200 350HP...
Page 19: ...SECTION 2 TS32 USER MANUAL 19 Figure 2 7 Compressor Discharge System Water cooled 200 350HP...
Page 20: ...TS32 USER MANUAL SECTION 2 20 Figure 2 8 Control System START Typical...
Page 21: ...SECTION 2 TS32 USER MANUAL 21 Figure 2 9 Control System MODULATION Typical...
Page 22: ...TS32 USER MANUAL SECTION 2 22 Figure 2 10 Control System UNLOAD Typical...
Page 23: ...SECTION 2 TS32 USER MANUAL 23 Figure 2 11 Control System FULL LOAD Typical...
Page 26: ...TS32 USER MANUAL SECTION 2 26 Figure 2 12 Compressor Air Inlet System...
Page 30: ...TS32 USER MANUAL SECTION 3 30 Figure 3 2 Identification Air Cooled 02250126 376 R02...
Page 32: ...TS32 USER MANUAL SECTION 3 32 Figure 3 2 Identification Water Cooled 02250126 378 R03...
Page 50: ...TS32 USER MANUAL SECTION 3 50 Figure 3 9 Wiring Diagram Air Cooled SSRV 02250178 844 R03...
Page 54: ...NOTES 54...
Page 78: ...NOTES 78...
Page 79: ...NOTES 79...