By convention, fuel gas hoses and fittings have left-hand threads.
All other hoses and fittings are right-handed.
1. Turn on exhaust system and blow out all hoses into exhaust hood
or plenum using dried/filtered compressed air. Make sure there is
no oil or dust in any of the hoses. Oil or grease in the hoses, espe-
cially the oxygen hose, can cause a fire.
2. Connect all hoses to auxiliary equipment. Tighten all fittings firmly
but do not overtighten.
3. Connect oxygen hose to spray gun first. Then connect air and fuel
gas hoses.
4. One at a time, open gas supply valves and regulators. Check and
correct for leaks. Use a non-residual leak check solution.
5. Purge the spray gun: Open the air supply regulator and set the
spray gun gas head valve to the full run position. Allow the gun to
purge for approximately 5 seconds.
The system is installed and ready for operation.
CAUTION
Always turn on exhaust
system whenever vent-
ing gas.
WARNING
FIRE HAZARD!
Always make sure the
hoses are free of oil or
grease.