16E / 16E-H / 16E-P Spray Gun
40
MAN 96150 EN 01
5.5
Lighting Flow Check
Normal gas flow ranges with the gas head valve in the lighting position
are given below. Flows lower than those shown indicate a possible
blockage on a valve core bleeder port. Higher flows may mean a leaky
valve seal.
Fuel Gas
Wire
Size
Lighting Pressure
Lighting Flows (3GF Flowmeter Reading)
Oxygen
Fuel
Oxygen Scale
Acetylene Scale
bar
PSI
bar
PSI
NLPM
SCFH
NLPM
SCFH
Acetylene
3/16”
2.6
38
1
15
19 - 29
46 - 64
1½ - 2½
3 - 5
1/8”
2.6
38
1
15
19 - 29
46 - 64
1½ - 2½
3 - 5
11 ga.
1.7
25
1
15
15 - 22
36 - 50
1½ - 2½
3 - 5
15 ga.
1.7
25
1
15
14 - 20
34 - 48
1½ - 2½
3 - 5
Propane
3/16”
2.9
42
2.6
38
24 - 32
55 - 72
2 - 3
4 - 7
1/8”
3.2
47
2.9
42
24 - 32
55 - 72
2 - 3
4 - 7
11 ga.
2.4
35
2.1
30
19 - 26
46 - 60
2 - 3
4 - 7
15 ga.
2.1
30
2.1
30
17 - 24
40 - 55
2 - 3
4 - 7