Operation & Maintenance Manual
23
Cyclo® BBB5
Cyclo® BBB5
3
Carefully remove the unit Air Breather assembly and put aside for reinsertion after
oil fill process is complete .
4
Slowly fill the Cyclo® (input) portion with the correct type and grade of oil as used in
STEP #2 of this process .
NOTE:
The oil fill cup may immediately become full during the process . In such an
event, stop the fill process and allow the oil to drain from the cup into the reducer .
5
The input portion is considered full when the oil level stabilizes in the middle of the
oil sight gauge .
Check gauge carefully . Oil film from fill procedure can distort view .
Be sure to check the oil level after a few minutes of operation . Stop
equipment and check gauge as shown in step 5 . Adjust oil level as required .
6
Once the input portion of the unit is filled to the correct level with lubricant,
carefully reinsert the air breather assembly into the oil fill cup .
Y2 Oil Fill & Drain Procedures,
continued
Oil Fill Process
Fill cup
Air breather
Air breather