20
Operation & Maintenance Manual
Cyclo® HBB
Cyclo® HBB
5
Place a soft-metal (i e brass) bar against the flange of the Taper-Grip® Bushing and
carefully strike end of bar with a hammer to release the bushing.
6
After releasing the bushing, reinstall the cap screws by hand only Stop tightening
them when they touch the thrust collar They will ensure the reducer will not slide
against the bushing and clamp it against the shaft when the reducer is removed
Apply a liquid penetrant to the shaft where it contacts the bushing Allow time for
the liquid to penetrate between the shaft and the bushing wall Once the penetrant
has settled adequately, carefully remove the Cyclo® HBB from the driven shaft
Note: If the Taper-Grip® Bushing releases, but the unit cannot be
removed from the driven shaft, a puller may need to be applied to the
bushing flange to pull the unit free from the shaft
Removal from Driven Shaft
Cyclo® HBB with Taper-Grip® Bushing
Summary of Contents for Cyclo HBB
Page 1: ...0 7 6 0 1 6 0 0 0 3 H B B O M2 0 1 8...
Page 27: ...MA X MI N...