Copyright © 2011 Sumitomo Electric Industries, LTD.
SMF : G.652, G.657
MMF : MM50(OM2), MM50(OM3), MM50(OM4), MM62.5(OM1)
The Lynx-CustomFit® Splice-On Connector is designed and
manufactured to assure personal safety. Improper operation
can result in bodily injury and serious damage to this product.
Please read and observe all warnings instructions given in this
operation manual.
Wear safety glasses
to protect your eyes when
handling optical fiber.
Never look into
the end of a microscope or optical
cable connected to an optical output device that is
operating. Laser radiation is invisible, and direct
exposure can severely injure the human eye.
Alcohol is flammable
, causes irritation and is harmful
if swallowed or inhaled. Keep alcohol away from
heat, sparks, skin, and avoid contact with eyes.
In the case of the work at the high place, please be
careful not to drop an assembling tool.
Lynx-CustomFit® Splice-On Connector Ver. 2
- LYNX2-SC for 250um or 900um Tight Buffered Fiber -
Installation Manual
!
!
!
1. Improper assembly will result in a loss of performance.
Please read instructions
given in this operation manual
and the operation manual of the fusion splicer.
2.
Never touch the fiber of the stub
. It has been inspected
in the factory.
3. The product is sensitive to dirt or dust. Do not take out
any parts from the package
until it is to be used
.
4. The characteristic will be influenced by the fiber
cleaved surface condition. Please use a cleaver which
has a good cleaving characteristic.
5. Do not remove the dust cap
until the connector has
been completely assembled
in order not to cause an
high insertion loss due to them.
For your safety operation
!
Precautions
Composition
Disposable
Holder (*1)
Outer
Housing
Inner
Housing
Rear
Stopper
Ferrule
Subassembly
Boot
Furcation
Tube
Protection Sleeve
and Spring
(*1) 1 pc / 100 connectors
Assembling Tools
Fusion Splicer
T-Q101-CA(71C), etc.
Fiber Cleaver
FC-6S-C, etc.
Jacket remover
JR-M03, etc.
Recommended Program
Splicer
Fiber
Splicing Program
Heater Program
T-25eS
SMF
SM1: SMF1C
Lynx
or FPS (60mm)
MMF
MM1: MMF1C
T-39FH
SMF
LYNX-SM
Lynx
or FPS (60mm)
MMF
LYNX-MM
T-Q101-CA
(T-71C)
SMF
Standard SMF
Lynx
or 60mm 0.9
MMF
MMF 50&62.5
Please perform Arc test prior to the splicing operation.
(See the operation manual of the splicer.)
*Fiber for testing is not included in the kit.
Please check fiber type inside the field fiber.
ETK1123068D
Holder Type
Cleave length: 10mm
Holder (Fiber Side)
for 900um tight buffer
for 250um fiber
LYNX2-UML-S
FHS-09
FHS-025
LYNX2-S-LB5
Below equipment or tool are examples.
Either one holder is required.
North Carolina (USA)
Sumitomo Electric Lightwave Corp.
78 Alexander Drive, P.O. Box 13445, RTP, NC 27709
TEL +1-919-541-8100
http://www.sumitomoelectric.com/
Yokohama (Japan)
Sumitomo Electric Industries, Ltd.
(Lightwave Network Products Division)
1, Taya-cho, Sakae-ku, Yokohama 244-8588, Japan
TEL +81-45- 853-7223, http://global-sei.com/fttx/
London (UK)
Sumitomo Electric Europe Ltd.
220 Centennial Avenue, Elstree, Herts. WD6 3SL, UK
TEL +44 (0)20-8953-8118