LYNX2-FC for 250um or 900um Tight Buffer
Assembly Procedure
ETK1123070A
(1) Slide Rear Parts onto the
fiber.
Insert fiber into
this hole
(2) Slide Protection Sleeve onto the
fiber.
(3) Remove the fiber coating.
Approx. 35mm (JR-M03)
0.9 to 0.25mm
0.25 to 0.125mm
(4) Clean the fiber with lint-
free cleaning wipe.
Moistened
with alcohol
(5) Set the fiber on the holder.
Confirm the position
Good
No Good
No Good
Do not touch
bare fiber
1. Place
3. Slide
Clean rubber clamp
and blade regularly
(6) Cleave the fiber (FC-6S)
No gap
(7) Set fiber holder on the splicer
(left side).
Grasp here to
pick up
Do not touch
bare fiber
(8) Pick up the stub and set the stub on the plastic holder.
(9) Set stub holder on the splicer
(right side).
Place fiber on
V-groove gently
If the position of the fiber is wrong,
set the fiber or stub again.
(10) Fusion Splice.
Lightly holding assembly to prevent bending
(11) Open the stub and fiber holders.
Lightly maintaining tension to
prevent bending
(12) Pick up the spliced fiber.
No twisting
(13) Slide Protection until it covers the projection of
the flange.
(14) Set Sleeve into the heater.
No twisting
(15) Confirm the position before
heating.
Sleeve at center
of heater
No gap
Button to
start heating
(16) Heat Protection Sleeve.
Lynx heater program runs a fan to
cool the sleeve after heating
(17) Pick up Sleeve.
Be careful for hot sleeve,
spring and flange even after
the cooling by fan.
!
2. Close
Push to
close
Lightly maintaining
tension on fiber
Right side first
Then left side
No twisting
Left side first
Then right side
Button to
start splicing
Place fiber on
V-groove gently
Window
Window
Align windows and dot
APC - Red dot
PC/UPC - Black dot
(18) Put Front Parts.
(19) Remove Dummy Cap.
Cut Tether
Complete
(A) Set Fusion Condition
Push “power
key” for more
than 1 sec.
“Main Menu”
Select Fiber Type
Select “Fiber Type”, then “Return”.
(B) Perform Arc Test
Select “Arc Test”
Then perform the arc test
according to the
instruction.
*Fiber for testing is not
included in the kit.
Please check fiber type
inside the field fiber.
“Main Manu”
Select Sleeve Type
Select Sleeve Type
Then “Return”
See the operation manual of each splicer. These are the example of T-Q101-CA (T-71C).