LYNX2-FC for 250um or 900um Tight Buffer

Assembly Procedure

ETK1123070A

(1) Slide Rear Parts onto the
fiber.

Insert fiber into 

this hole

(2) Slide Protection Sleeve onto the
fiber.

(3) Remove the fiber coating.
Approx. 35mm (JR-M03)

0.9 to 0.25mm

0.25 to 0.125mm

(4) Clean the fiber with lint-
free cleaning wipe.

Moistened 

with alcohol

(5) Set the fiber on the holder.

Confirm the position 

Good 

No Good 

No Good 

Do not touch 

bare fiber

1. Place

3. Slide

Clean rubber clamp 

and blade regularly

(6) Cleave the fiber (FC-6S)

No gap

(7) Set fiber holder on the splicer 
(left side).

Grasp here to 

pick up

Do not touch 

bare fiber

(8) Pick up the stub and set the stub on the plastic holder.

(9) Set stub holder on the splicer 
(right side).

Place fiber on 

V-groove gently

If the position of the fiber is wrong,

set the fiber or stub again.

(10) Fusion Splice.

Lightly holding assembly to prevent bending

(11) Open the stub and fiber holders.

Lightly maintaining tension to 

prevent bending

(12) Pick up the spliced fiber.

No twisting

(13) Slide Protection until it covers the projection of 
the flange.

(14) Set Sleeve into the heater.

No twisting

(15) Confirm the position before

heating.

Sleeve at center 

of heater

No gap

Button to 

start heating

(16) Heat Protection Sleeve.

Lynx heater program runs a fan to 

cool the sleeve after heating

(17) Pick up Sleeve.

Be careful for hot sleeve,

spring and flange even after

the cooling by fan.

!

2. Close

Push to

close

Lightly maintaining 

tension on  fiber

Right side first

Then left side

No twisting

Left side first

Then right side

Button to 

start splicing

Place fiber on 

V-groove gently

Window

Window

Align windows and dot

APC - Red dot
PC/UPC - Black dot

(18) Put Front Parts.

(19) Remove Dummy Cap.

Cut Tether

Complete

(A) Set Fusion Condition

Push “power

key” for more

than 1 sec.

“Main Menu”

Select Fiber Type

Select “Fiber Type”, then “Return”.

(B) Perform Arc Test

Select “Arc Test”

Then perform the arc test
according to the
instruction.
*Fiber for testing is not 
included in the kit. 
Please check fiber type 
inside the field fiber.

“Main Manu”

Select Sleeve Type

Select Sleeve Type

Then “Return”

See the operation manual of each splicer. These are the example of T-Q101-CA (T-71C).