4-7
<Splice program settings>
The item with an arrow can
only be edited.
All items can be edited in Ad-
ministrator mode.
Item
Details
Name
Allows to edit splice program name.
Abbreviated name
Allows to edit splice program name which is displayed on the main
splice screen.
Template
Allows to choose splice program as a template when new splice
program is created.
Note
Allows to add a note to the selected splice program (up to 21
characters).
Arc Power
Allows to manually adjust the arc power for fusion splicing. Since
an arc test automatically optimizes the power, it is not necessary to
adjust it manually under normal use. If the level of an arc needs
changing, the arc power should be adjusted manually.
Gapset
Position
Allows to manually adjust the fiber position for fusion splicing.
Since an arc test automatically optimizes the position, it is not
necessary to adjust it manually under normal use. If the position
needs changing, it should be adjusted manually.
Cleaning Arc Time
Sets the cleaning arc time to remove dust from optical fiber.
Cleaning Arc Power
Allows to adjust power for cleaning arc based on the standard arc
power.
Cleave Angle Limit
Sets the threshold of cleave angle. If a reading exceeds the
threshold, the splicer will give an error.
Arc Time
Sets the arc fusion time.
Est. Loss Limit
Sets the threshold of estimated loss. If a reading exceeds the
threshold, the splicer will give an error.