Error message list
Please contact maintenance service center when it is not recovered if you take the
measures below.
Error message
Description and measure
Alignment Error
[Description]
(L)(R)(LR)
There is dust in the V-groove.
There is dust on the fiber.
[Measure]
Clean the V-groove.
Re-cleave the fiber.
Brightness Error
[Description]
Brightness Various Error
The splicer failed in LED brightness adjustment.
LED error
[Measure]
Clean the LED, the mirror protection glass and the microscope lens.
CAMERA ERROR
[Measure]
Turn off the power and turn it on again. If the error still persists,
contact our maintenance service center.
Cut Error (Angle)
[Description]
(L)(R)(LR)
The cleave angle exceeds the allowable level.
[Measure]
Re-cleave the fiber.
Cut Error (Crack)
[Description]
(L)(R)(LR)
The splicer detected crack in an end-face inspection
[Measure]
Re-cleave the fiber.
Cut Error (LIP)
[Description]
(L)(R)(LR)
The splicer detected lip in an end-face inspection
[Measure]
Re-cleave the fiber.
Cut Error (Projection)
[Description]
(L)(R)(LR)
The splicer detected projection in an end-face inspection
[Measure]
Re-cleave the fiber.
DEVICE ERROR
[Description]
The controlboard has a problem.
[Measure]
Please contact our maintenance service center.
52
Summary of Contents for TYPE-66M12
Page 67: ...57...