Error message
Description and measure
Diameter Check Error
[Description]
(L)(R)(LR)
The spicer failed in image processing and the fiber diameter was not
analyzed.
[Measure]
Place the fiber in the V-groove again.
Dust Error
[Description]
(L)(R)(LR)
There is dust or dirt on the fiber.
[Measure]
Re-cleave the fiber.
End Check Error
[Description]
(L)(R)(LR)
The spicer failed in image processing and the fiber end was not
analyzed.
[Measure]
Place the fiber in the V-groove again.
Fiber Check Error
[Description]
(L)(R)(LR)
The fiber is not placed in the V-groove properly.
[Measure]
Place the fiber in the V-groove again.
Fiber Count Error
[Description]
(L)(R)(LR)
The number of the fiber being spliced is different from the settings.
[Measure]
Check that the number of the fiber being spliced matches with the
settings.
Fiber Pitch Error
[Description]
(L)(R)(LR)
The fiber pitch exceeds the allowable level.
[Measure]
Place the fiber into the V-groove again.
Gap Error
[Description]
Irregularity Error
The irregularity of the fiber end exceeds the allowable level.
(L)(R)(LR)
[Measure]
Recleave the fiber.
Hood Open Error
[Description]
The hood is not closed completely.
[Measure]
Close the hood completely.
53