SummaCut cutter
User’s Manual
Setup
1-9
1.3
Connecting the Cutter to the Mains
1.3.1
Grounding (“Earthing”)
CAUTION:
An insulated ground conductor must be installed as part of the branch circuit that
supplies power to the wall outlet to which the cutter is connected. The ground conductor
must have the same size, insulation material and thickness as the grounded and ungrounded
branch circuit supply conductors, but the insulating seat should be green or green with
yellow striping.
The ground conductor described above must be grounded at the electrical distribution
board or, if power is supplied by a separate system, at the power supply transformer/motor
generator set.
The wall sockets into which the cutter is plugged must be of the grounded type. The
grounded conductors serving the wall socket must be properly connected to the ground.
For emergency access, the cutter should be installed near the socket-outlet for easy access.
MAKE SURE THIS
IS CONNECTED TO A
MAKE SURE THIS IS
CONNECTED TO A
THREE-PIN
PLUG
EUROPE:
USA
OUTLET
:
THREE-PIN
KNOWN GROUND
KNOWN EARTH
FIG 1-12
1-12
PROPERLY GROUNDED CONNECTION
1.3.2
Operating voltage
CAUTION:
Before changing the fuse, make sure that the cutter is completely disconnected
from its power source.
CAUTION:
For continued protection against risk of fire, replace only with the same type and
rating of fuse.
Fuse Rate: T2.0A, 250V SCHURTER SPT OR EQUIVALENT.
The power supply detects the line voltage and switches automatically between 110V and
230V.