26.
HIGH LINE VOLTAGE
Cause:
The secondary voltage of the transformer is measured by the µP on the PCB. When it
measures a value higher than the upper limit setting, the machine will give this error. This is a
fatal error. Switching the power off and making a corrective action is the only solution.
Action:
27.Measure the line voltage. Check whether the voltage selector at the back of the machine
is set to the correct line voltage. The line voltage should be between the selected
v8% or -10%.
28.Check the secondary voltage of the transformer. It should be less than 30VAC. If that is
not the case, replace the transformer.
29.Check the DC voltage on the PCB. It should be less than 37VDC.
30.Replace the main PCB.
31.
ILLEGAL PLOT COMMAND
Cause:
For
DMPL,
when a wrong set of instruction is sent to the machine. This message only
appears when the machine is configured to report DMPL ERRORS.
Action:
32.Set DM/PL ERRORS to IGNORED in the MENU to avoid this message.
33.If the cut result is not satisfactory, lower the baud rate at the machine side and at the
computer side. If the parallel interface is used, make the cable shorter.
34.Check the cut file for unknown dm/pl commands.
35.
ILLEGAL CLIP & SCALE SETTINGS
Cause:
Appears when wrong parameters are sent after a W command in
DMPL
. This message only
appears when the machine is configured to report DMPL ERRORS.
Action:
36.Set DM/PL ERRORS to IGNORED in the MENU to avoid this message.
37.If the cut result is not satisfactory, lower the baud rate at the machine side and at the
computer side. If the parallel interface is used, make the cable shorter.
38.Check the cut file for unknown dm/pl commands.
39.
SYNTAX ERROR
Cause:
5-4
Troubleshooting-Error Codes
Summary of Contents for SummaSign D1010
Page 1: ...Service Manual SummaSign Series Summa NV Rochesterlaan 6 8470 Gistel Belgium...
Page 80: ...SummaSign Service Manual 106 107 2 36 Replacements Guidelines Blank page...
Page 85: ...Service Manual SummaSignT se 3 2 OPERATING VOLTAGE CONVERSION Maintenance and Cleaning 3 5...
Page 87: ...Service Manual SummaSignT se Maintenance and Cleaning 3 7 blank page...
Page 92: ...Service Manual SummaSign Calibration 4 5...
Page 93: ...SummaSign Service Manual HEAD CALIBRATION 4 6 Calibration...
Page 131: ...Service Manual SummaSign Spare Parts List 7 13...
Page 134: ...Summasign Service Manual 7 16 Spare Parts List...