Service Manual
SummaSign series Cutters
MEDIA SENSOR
The MEDIA SENSOR submenu is used to activate or deactivate the media sensors.
On the LCD, the active setting is marked with an *.
The sensors detect whether media is loaded or detect the end of media. The sensors
prevent damage to the cutting strip and knife tip.
AUTOLOAD
The AUTOLOAD option enables the user to the change the vinyl unroll proceedings.
When AUTOLOAD is ON , the cutter will automatically unroll the vinyl when needed.
When the AUTOLOAD option is OFF, the operator himself should unroll enough media
before starting to cut.
The default setting is ON. The best results and performance are guaranteed when
using this setting. On the LCD display, the active setting is marked with
an *.
TOOL COMMAND
The TOOL COMMAND is used to determine whether the DM/PL and HP/GL pen/knife-
select commands (the P and SP commands respectively) are ignored or accepted.
When the TOOL COMMAND option is set to “ACCEPT”, the P or SP commands will
change the selected tool in the cutter according to the suffix that follows the pen/knife
command. The cutter’s LCD will, e.g. prompt the user with the following message:
“INSERT PEN” when a P2 command is sent. When the TOOL COMMAND option is set
to “IGNORE”, the pen/knife commands are ignored.
On the LCD, the active setting is marked with an *. The default setting is “ACCEPT”.
LOAD ON W COMMAND
The LOAD ON W CMD submenu will only be displayed if the PLOT LANGUAGE is set
to DM/PL (See Paragraph 1.4.4.). The LOAD ON W CMD determines, when receiving
the DM/PL Window-command (W-command), whether aside from the scaling function,
media is loaded or not. Besides scaling, the W-command is also very useful when
cutting long signs. With the W-command, media loading will go smoother. Sufficient
media will be pulled off the roll at once. Even when AUTOLOAD is off, there is no need
anymore to unroll the media manually.
Keyboardcontrols
1-17
Summary of Contents for SummaSign D1010
Page 1: ...Service Manual SummaSign Series Summa NV Rochesterlaan 6 8470 Gistel Belgium...
Page 80: ...SummaSign Service Manual 106 107 2 36 Replacements Guidelines Blank page...
Page 85: ...Service Manual SummaSignT se 3 2 OPERATING VOLTAGE CONVERSION Maintenance and Cleaning 3 5...
Page 87: ...Service Manual SummaSignT se Maintenance and Cleaning 3 7 blank page...
Page 92: ...Service Manual SummaSign Calibration 4 5...
Page 93: ...SummaSign Service Manual HEAD CALIBRATION 4 6 Calibration...
Page 131: ...Service Manual SummaSign Spare Parts List 7 13...
Page 134: ...Summasign Service Manual 7 16 Spare Parts List...