INTERNAL TESTS SUBMENUS
TANG. KNIFE CALIBRATION
The purpose of the knife calibration routine is to detect and, if need be, to correct
problems related with the concentricity of the TANGENTIAL knife blade. This routine
should only be run when required. When noticing cut quality problems with a new knife,
perform a knife calibration test as described in the following paragraphs.
During the knife calibration routine, the cutter will cut a series of test patterns which will
allow you to identify errors in knife rotation and concentricity. Corrective measures can
be taken using the control panel keys.
Knife calibration errors may be due to any of the following causes (see Fig. 1-5):
Concentricity misalignment
. The knife tip is slightly rotated in relation to its
theoretical 0
angle. This error can be corrected by means of the ADJUST
ORIGIN test routine.
Horizontal misalignment
. The knife tip deviates from its theoretical longitudinal
centre. This error can be corrected by means of the ADJUST LONG. test routine.
1-20
Keyboardcontrols
Summary of Contents for SummaSign D1010
Page 1: ...Service Manual SummaSign Series Summa NV Rochesterlaan 6 8470 Gistel Belgium...
Page 80: ...SummaSign Service Manual 106 107 2 36 Replacements Guidelines Blank page...
Page 85: ...Service Manual SummaSignT se 3 2 OPERATING VOLTAGE CONVERSION Maintenance and Cleaning 3 5...
Page 87: ...Service Manual SummaSignT se Maintenance and Cleaning 3 7 blank page...
Page 92: ...Service Manual SummaSign Calibration 4 5...
Page 93: ...SummaSign Service Manual HEAD CALIBRATION 4 6 Calibration...
Page 131: ...Service Manual SummaSign Spare Parts List 7 13...
Page 134: ...Summasign Service Manual 7 16 Spare Parts List...