SENSOR SETUP
The SENSOR SETUP option is a useful routine to check whether or not the front and
rear media sensor are functioning properly and whether the switching levels of these
sensors are correctly set.
CALIBRATION
Calibration allows the length of the lines cut to be adjusted to within the specifications.
For instance, if a cut line should measure 100 mm exactly, the cutter can be adjusted
for any discrepancy.
TRACKING TEST
This test allows the tracking quality of the machine to be verified.
FRICTION PLOT
This test routine must be performed with a pen and is used to detect problems with the
cutter. The FRICTION PLOT is automatically scaled to fit the currently installed paper
size. This test should only be performed by qualified service personnel.
RS232 TEST
The RS232 TEST routine verifies the cutter’s RS-232-C serial communications
(transmit data, receive data, and hardware handshaking) circuits. This test does not
require pen, knife or media to be loaded.
To run the RS-232-C test, proceed as follows :
1. Unplug the RS-232-C data cable from the rear panel of the cutter.
2. Use a loopback test cable to connect pin 2 of the cutter’s data connector to pin 3
and pin 7 to pin 8.
3. With RS232 TEST displayed, press the ENTER key. The cutter will start transmitting
and receiving data at all available baud rates and parity settings. The length of
the transmissions will vary because of the different baud rates used. The unit
then checks the hardware handshake lines.
4. Upon completion of the test, remove the loopback test cable from the cutter rear
panel RS-232-C connector.
5. Plug the RS-232-C data cable into the connector.
RAM TEST
This test completely checks the RAM bit for bit.
1-28
Keyboardcontrols
Summary of Contents for SummaSign D1010
Page 1: ...Service Manual SummaSign Series Summa NV Rochesterlaan 6 8470 Gistel Belgium...
Page 80: ...SummaSign Service Manual 106 107 2 36 Replacements Guidelines Blank page...
Page 85: ...Service Manual SummaSignT se 3 2 OPERATING VOLTAGE CONVERSION Maintenance and Cleaning 3 5...
Page 87: ...Service Manual SummaSignT se Maintenance and Cleaning 3 7 blank page...
Page 92: ...Service Manual SummaSign Calibration 4 5...
Page 93: ...SummaSign Service Manual HEAD CALIBRATION 4 6 Calibration...
Page 131: ...Service Manual SummaSign Spare Parts List 7 13...
Page 134: ...Summasign Service Manual 7 16 Spare Parts List...