OPERATING VOLTAGE CONVERSION
The power entry module cover shows four possible AC voltage settings (100 V, 120 V,
220 V and 240 V). The pin in one of the holes indicates the cutter's active voltage
setting. If this setting does not match the voltage supplied to your site, you must
change the voltage
BEFORE
powering on the cutter.
When changing the voltage setting, you will also have to change the fuses as
appropriate to the voltage.
To change the fuse(s), remove the fuse(s) from the fuse box behind the cover plate of
the power entry module.
For 100 or 120 V AC operation of cutters with 1 x-motor Pro unly 1.0 A Slo-Blo fuses.
For 100 or 120 V AC operation of cutters with 2 x-motorsT750T,only 1.25 A Slo-Blo
fuses.
For 220 or 240 V AC operation of cutters with 1 x-motor , Pr0.5 A Slo-Blo fuses.
For 220 or 240 V AC operation of cutters with 2 x-motors /T1010 Pro/TusSlo-Blo fuses.
NOTE
Always make sure that you are using the correct fuses for your
voltage selection.
POWER ENTRY MODULE
3-6
Maintenance and Cleaning
Summary of Contents for SummaSign D1010
Page 1: ...Service Manual SummaSign Series Summa NV Rochesterlaan 6 8470 Gistel Belgium...
Page 80: ...SummaSign Service Manual 106 107 2 36 Replacements Guidelines Blank page...
Page 85: ...Service Manual SummaSignT se 3 2 OPERATING VOLTAGE CONVERSION Maintenance and Cleaning 3 5...
Page 87: ...Service Manual SummaSignT se Maintenance and Cleaning 3 7 blank page...
Page 92: ...Service Manual SummaSign Calibration 4 5...
Page 93: ...SummaSign Service Manual HEAD CALIBRATION 4 6 Calibration...
Page 131: ...Service Manual SummaSign Spare Parts List 7 13...
Page 134: ...Summasign Service Manual 7 16 Spare Parts List...